Automatic Transaxle - 6 Speed DTCS
DIAGNOSTIC TROUBLE CODE LIST
| Five Digit DTC | Component | Description | Condition | Symptom | Perform Test |
|---|---|---|---|---|---|
| P0706 | TR sensor | TR sensor range or performance error | TR sensor signal is out of normal range | TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. | Install a new TCM. |
| P0707 | TR sensor | TR sensor circuit low input | TR sensor signal is below threshold of 0.127 volts, sensor/circuit electrical malfunction | TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. | Install a new TCM. |
| P0708 | TR sensor | TR sensor circuit high input | TR sensor signal is above threshold of 4.87 volts, sensor/circuit electrical malfunction | TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. | Install a new TCM. |
| P0711 | TFT sensor | No change in TFT during operation | PCM has detected no TFT change during operation. TFT value stuck at some normal reading | TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. | GO to PINPOINT TEST B . |
| P0712 | TFT sensor | 200°C (329°F) indicated, TFT sensor circuit grounded | Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) | TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. | GO to PINPOINT TEST B . |
| P0713 | TFT sensor | -43°C (-45°F) indicated, TFT sensor circuit grounded | Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) | TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. | GO to PINPOINT TEST B . |
| P0716 | TSS sensor | TSS range out of performance, insufficient input from TSS | PCM has detected a loss or noisy TSS signal during operation | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST D . |
| P0717 | TSS sensor | No TSS signal | PCM has not detected a TSS signal. No TSS signal when OSS signal present | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST D . |
| P0721 | OSS sensor | OSS range out of performance, insufficient input from OSS | PCM has detected a loss or noisy OSS signal during operation | No adaptive or self learning strategy. | GO to PINPOINT TEST C . |
| P0722 | OSS sensor | No OSS signal | PCM has detected no TSS signal | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST C . |
| P0729 | Transaxle | 6th gear ratio | No 6th gear ratio detected by TCM | No 6th gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0730 | Clutch control solenoids or internal parts | Gear ratio error | PCM has detected a gear ratio error | No self learning strategy. | GO to PINPOINT TEST A . |
| P0731 | Solenoid or internal parts | 1st gear ratio | No 1st gear ratio detected by TCM | No 1st gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0732 | Solenoid or internal parts | 2nd gear ratio | No 2nd gear ratio detected by TCM | No 2nd gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0733 | Solenoid or internal parts | 3rd gear ratio | No 3rd gear ratio detected by TCM | No 3rd gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0734 | Solenoid or internal parts | 4th gear ratio | No 4th gear ratio detected by TCM | No 4th gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0735 | Solenoid or internal parts | 5th gear ratio | No 5th gear ratio detected by TCM | No 5th gear, no TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0736 | Transaxle | Reverse gear ratio | No reverse gear ratio detected by TCM | No reverse gear, no self learning strategy. | GO to PINPOINT TEST A . |
| P0817 | TCM/PCM starter circuit | Starter disable circuit open or shorted to power/ground | TCM detected a failure in the starter lock circuit, failed ON or OFF Ignition switch is ON, TCM and PCM communication is normal. No voltage is detected on the start lock circuit for more than 0.1 second or a continuous 12-volt output is detected for more than 0.1 second. Conditions present 2 times to set DTC | DTC is set. Warning lamp is illuminated. | GO to PINPOINT TEST E . |
| P0961 | PCA | PCA circuit or solenoid failure | PCA circuit or solenoid (SLT) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0962 | PCA | PCA solenoid signal or grounded circuits either short or open, solenoid circuit failure | Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0963 | PCA | PCA solenoid short to power circuit failure | Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0973 | SSA | SSA solenoid or circuit shorted to ground | Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0974 | SSA | SSA solenoid or circuit shorted to power or open | Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0976 | SSB | SSB solenoid or circuit shorted to ground | Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0977 | SSB | SSB solenoid or circuit shorted to power or open | Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0978 | SSC | SSC circuit or solenoid failure | SSC circuit or solenoid (SLC1) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0979 | SSC | SSC solenoid signal or grounded circuits either shorted or open, solenoid circuit failure | Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0980 | SSC | SSC solenoid or circuit shorted to power | Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0981 | SSD | SSD circuit or solenoid failure | SSD circuit or solenoid (SLC2) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0982 | SSD | SSD solenoid signal or grounded circuits either shorted or open, solenoid circuit failure | Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0983 | SSD | SSD solenoid or circuit shorted to power | Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0984 | SSE | SSE circuit or solenoid failure | SSE circuit or solenoid (SLC3) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0985 | SSE | SSE solenoid signal or grounded circuits either shorted or open, solenoid circuit failure | Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0986 | SSE | SSE solenoid or circuit shorted to power | Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0997 | SSF | SSF circuit or solenoid failure | SSF circuit or solenoid (SLB1) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0998 | SSF | SSF solenoid signal or grounded circuits either shorted or open, solenoid circuit failure | Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P0999 | SSF | SSF solenoid or circuit shorted to power | Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P1657 | TCM | TCM communication link error | CAN link error detected by PCM | No engagements, no adaptive or self learning strategy. Limited fuel and spark. | Install a new transmission control module (TCM). |
| P1719 | PCM/TCM CAN | Engine torque signal error | Engine torque calculation signal received from PCM is inaccurate based on actual vehicle operating conditions | Engine concerns may be present that cause the transaxle not to operate correctly. | DIAGNOSE and REPAIR all engine concerns. CLEAR DTCs, road test the vehicle and rerun OBD. |
| P2757 | TCC solenoid | TCC solenoid circuit failure, stuck OFF | TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostic | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P2758 | TCC solenoid | TCC solenoid circuit failure, stuck ON | TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostics | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P2762 | TCC solenoid | TCC circuit or solenoid failure | TCC circuit or solenoid (SLU) failed during operation. Incorrect commanded current detected by TCM | No engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P2763 | TCC solenoid | TCC circuit shorted to power | TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit shorted to power | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |
| P2764 | TCC solenoid | TCC solenoid signal or grounded circuits either short or open solenoid circuit failure | TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid | No TCC engagements, no adaptive or self learning strategy. | GO to PINPOINT TEST A . |