LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2005 >> Freestyle Limited, FWD >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Automatic Transaxle - 6 Speed DTCS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Automatic Transaxle - 6 Speed DTCS

DIAGNOSTIC TROUBLE CODE LIST

Five Digit DTC Component Description Condition Symptom Perform Test
P0706 TR sensor TR sensor range or performance error TR sensor signal is out of normal range TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0707 TR sensor TR sensor circuit low input TR sensor signal is below threshold of 0.127 volts, sensor/circuit electrical malfunction TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0708 TR sensor TR sensor circuit high input TR sensor signal is above threshold of 4.87 volts, sensor/circuit electrical malfunction TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0711 TFT sensor No change in TFT during operation PCM has detected no TFT change during operation. TFT value stuck at some normal reading TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0712 TFT sensor 200°C (329°F) indicated, TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0713 TFT sensor -43°C (-45°F) indicated, TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0716 TSS sensor TSS range out of performance, insufficient input from TSS PCM has detected a loss or noisy TSS signal during operation No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST D .
P0717 TSS sensor No TSS signal PCM has not detected a TSS signal. No TSS signal when OSS signal present No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST D .
P0721 OSS sensor OSS range out of performance, insufficient input from OSS PCM has detected a loss or noisy OSS signal during operation No adaptive or self learning strategy. GO to PINPOINT TEST C .
P0722 OSS sensor No OSS signal PCM has detected no TSS signal No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST C .
P0729 Transaxle 6th gear ratio No 6th gear ratio detected by TCM No 6th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0730 Clutch control solenoids or internal parts Gear ratio error PCM has detected a gear ratio error No self learning strategy. GO to PINPOINT TEST A .
P0731 Solenoid or internal parts 1st gear ratio No 1st gear ratio detected by TCM No 1st gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0732 Solenoid or internal parts 2nd gear ratio No 2nd gear ratio detected by TCM No 2nd gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0733 Solenoid or internal parts 3rd gear ratio No 3rd gear ratio detected by TCM No 3rd gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0734 Solenoid or internal parts 4th gear ratio No 4th gear ratio detected by TCM No 4th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0735 Solenoid or internal parts 5th gear ratio No 5th gear ratio detected by TCM No 5th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0736 Transaxle Reverse gear ratio No reverse gear ratio detected by TCM No reverse gear, no self learning strategy. GO to PINPOINT TEST A .
P0817 TCM/PCM starter circuit Starter disable circuit open or shorted to power/ground TCM detected a failure in the starter lock circuit, failed ON or OFF Ignition switch is ON, TCM and PCM communication is normal. No voltage is detected on the start lock circuit for more than 0.1 second or a continuous 12-volt output is detected for more than 0.1 second. Conditions present 2 times to set DTC DTC is set. Warning lamp is illuminated. GO to PINPOINT TEST E .
P0961 PCA PCA circuit or solenoid failure PCA circuit or solenoid (SLT) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0962 PCA PCA solenoid signal or grounded circuits either short or open, solenoid circuit failure Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0963 PCA PCA solenoid short to power circuit failure Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0973 SSA SSA solenoid or circuit shorted to ground Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0974 SSA SSA solenoid or circuit shorted to power or open Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0976 SSB SSB solenoid or circuit shorted to ground Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0977 SSB SSB solenoid or circuit shorted to power or open Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0978 SSC SSC circuit or solenoid failure SSC circuit or solenoid (SLC1) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0979 SSC SSC solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0980 SSC SSC solenoid or circuit shorted to power Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0981 SSD SSD circuit or solenoid failure SSD circuit or solenoid (SLC2) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0982 SSD SSD solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0983 SSD SSD solenoid or circuit shorted to power Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0984 SSE SSE circuit or solenoid failure SSE circuit or solenoid (SLC3) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0985 SSE SSE solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0986 SSE SSE solenoid or circuit shorted to power Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0997 SSF SSF circuit or solenoid failure SSF circuit or solenoid (SLB1) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0998 SSF SSF solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0999 SSF SSF solenoid or circuit shorted to power Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P1657 TCM TCM communication link error CAN link error detected by PCM No engagements, no adaptive or self learning strategy. Limited fuel and spark. Install a new transmission control module (TCM).
P1719 PCM/TCM CAN Engine torque signal error Engine torque calculation signal received from PCM is inaccurate based on actual vehicle operating conditions Engine concerns may be present that cause the transaxle not to operate correctly. DIAGNOSE and REPAIR all engine concerns. CLEAR DTCs, road test the vehicle and rerun OBD.
P2757 TCC solenoid TCC solenoid circuit failure, stuck OFF TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostic No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2758 TCC solenoid TCC solenoid circuit failure, stuck ON TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostics No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2762 TCC solenoid TCC circuit or solenoid failure TCC circuit or solenoid (SLU) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2763 TCC solenoid TCC circuit shorted to power TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit shorted to power No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2764 TCC solenoid TCC solenoid signal or grounded circuits either short or open solenoid circuit failure TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .