LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2006 >> Crown Victoria Police Interceptor >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Automatic Transaxle/Transmission DTCS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Automatic Transaxle/Transmission DTCS

DIAGNOSTIC TROUBLE CODE CHART (DTC) LIST

DTC Component Description Condition Symptom Perform Test
P1702 Digital TR Intermittent DTC codes P0705 or P0708 Refer to DTC codes P0705 or P0708 condition. Refer to DTC codes P0705 or P0708. GO to PINPOINT TEST C .
P1704 Digital TR Digital TR circuit reading in between gear position during KOEO/KOER Digital TR sensor or selector lever cable incorrectly adjusted; or digital TR circuit failure. Wrong commanded EPC pressure. Digital TR reading the wrong gear position. GO to PINPOINT TEST C .
P0705 Digital TR Digital TR circuit failure Digital TR circuits, indicating an invalid pattern in TR_D. Condition caused by a short to ground or an open in TR4, TR3A, TR2 and/or TR1 circuits. This DTC cannot be set by an incorrectly adjusted digital TR sensor. Increase in EPC pressure (harsh shifts). Defaults to (D) or D for all gear positions. In (D) position trans, stuck in D or manual 2. GO to PINPOINT TEST C .
P0708 Digital TR Digital TR sensor circuit TR3A open Digital TR sensor circuit TR3A reading 2.6v - 5.0v (open circuit). This DTC cannot be set by an incorrectly adjusted digital TR sensor. Increase in EPC pressure. Defaults to (D) or D for all gear ranges. GO to PINPOINT TEST C .
P1705 Digital TR Digital TR self test was not carried out in PARK or NEUTRAL Vehicle not in PARK or NEUTRAL during on-board diagnostic. Rerun on-board diagnostic in PARK or NEUTRAL. GO to PINPOINT TEST C .
P0715 TSS Insufficient input from turbine shaft speed sensor PCM detected a loss of TSS signal during operation. Harsh shifts, harsh torque converter clutch activation and harsh engagements. GO to PINPOINT TEST F .
P0717 TSS Turbine shaft speed sensor signal intermittent PCM has detected an intermittent TSS signal. Harsh shifts, harsh torque converter clutch activation and harsh engagements. GO to PINPOINT TEST F .
P0718 TSS Turbine shaft speed sensor signal noisy PCM has detected a noisy TSS signal. Harsh shifts, harsh torque converter clutch activation and harsh engagements. GO to PINPOINT TEST F .
P0720 OSS Insufficient input from output shaft speed sensor PCM detected a loss of OSS signal during operation. Harsh shifts, abnormal shift schedule, no torque converter clutch activation. GO to PINPOINT TEST E .
P0721 OSS OSS sensor signal noisy PCM has detected an erratic OSS signal. Harsh shifts, abnormal shift schedule, no torque converter clutch engagement. GO to PINPOINT TEST E .
P0722 OSS wiring Insufficient input from OSS PCM has detected a loss of OSS signal. Harsh shifts, abnormal shift schedule, no torque converter clutch engagement. GO to PINPOINT TEST E .
P0731 SSA, SSB or internal parts 1st gear error No 1st gear. Incorrect gear selection, depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Engine rpm could be higher or lower than expected. Use the Solenoid Operation Chart, refer to PINPOINT TESTS - OSC EQUIPPED VEHICLE .
GO to PINPOINT TEST A .
P0732 SSA, SSB or internal parts 2nd gear error No 2nd gear. Incorrect gear selection, depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Engine rpm could be higher or lower than expected. Use the Solenoid Operation Chart, refer to PINPOINT TESTS - OSC EQUIPPED VEHICLE .
GO to PINPOINT TEST A .
P0733 SSA, SSB or internal parts 3rd gear error No 3rd gear. Incorrect gear selection, depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Engine rpm could be higher or lower than expected. Use the Solenoid Operation Chart, refer to PINPOINT TESTS - OSC EQUIPPED VEHICLE .
GO to PINPOINT TEST A .
P0734 SSA, SSB, or internal parts 4th gear error No 4th gear. Incorrect gear selection, depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Engine rpm could be higher or lower than expected. Use the Solenoid Operation Chart, refer to PINPOINT TESTS - OSC EQUIPPED VEHICLE .
GO to PINPOINT TEST A .
P0741 May also be generated by some other non-electric transmission hardware system. TCC, internal components TCC slippage detected The PCM picked up an excessive amount of slippage during normal vehicle operation. TCC slippage/erratic or no torque converter clutch operation. Flashing transmission control indicator lamp (TCIL). Refer to DIAGNOSIS BY SYMPTOM .
P0743 Output circuit check, generated only by electrical symptoms. TCC, wiring, PCM TCC solenoid circuit failure during on-board diagnostic TCC solenoid circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Short circuit: engine stalls in second (OD, 2 range) at low idle speeds with brake applied. Open circuit: torque converter clutch never engages. May flash TCIL. GO to PINPOINT TEST A .
P0750 Output circuit check, generated only by electrical symptoms. SSA, wiring, PCM SSA solenoid circuit failure SSA circuit failed to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See Solenoid On/Off Chart. GO to PINPOINT TEST A .
P0753 SSA, wiring, PCM SSA electrical failure SSA circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear depending on condition mode and manual lever position. See Solenoid On/Off Chart. May flash TCIL. GO to PINPOINT TEST A .
P0755 Output circuit check, generated only by electrical symptoms. SSB, wiring, PCM SSB solenoid circuit failure SSB circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See Solenoid On/Off Chart. GO to PINPOINT TEST A .
P0758 Output circuit check, generated only by electrical symptoms. SSB, wiring, PCM SSB electrical circuit failure SSB circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear depending on condition mode and manual lever position. See Solenoid On/Off Chart. May flash TCIL. GO to PINPOINT TEST A .
P1714 SSA, internal components SSA malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. See SOLENOID OPERATION CHART . GO to PINPOINT TEST G .
P1715 SSB SSB malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. See SOLENOID OPERATION CHART . GO to PINPOINT TEST G .
P0781 May also be generated by some other non-electric transmission hardware system. SSA or internal parts 1-2 shift error Engine rpm drop not detected when 1-2 shift was commanded by PCM. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Refer to SOLENOID OPERATION CHART , then GO to PINPOINT TEST A .
P0782 May also be generated by some other non-electric transmission hardware system. SSA, SSB or internal parts 2-3 shift error Engine rpm drop not detected when 2-3 shift was commanded by PCM. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Refer to SOLENOID OPERATION CHART , then GO to PINPOINT TEST A .
P0783 May also be generated by some other non-electric transmission hardware system. SSA, SSB or internal parts 3-4 shift error Engine rpm drop not detected when 3-4 shift was commanded by PCM. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). Refer to SOLENOID OPERATION CHART , then GO to PINPOINT TEST A .
P0713 TFT, wiring, PCM -40°C (-40°F) indicated TFT sensor circuit open Voltage drop across TFT sensor exceeds scale set for temperature -40°C (-40°F). Firm shift feel. GO to PINPOINT TEST B .
P1711 TFT TFT out of on-board diagnostic range Transmission not at operating temperature during on-board diagnostic. Warm vehicle to normal operating temperature. GO to PINPOINT TEST B .
P0712 TFT, wiring, PCM 157°C (315°F) indicated TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature of 157°C (315°F). Firm shift feel. GO to PINPOINT TEST B .
P1713 TFT wiring PCM TFT continually reading cold TFT sensor in range low failure. Firm shift feel. Substitute ECT for TFT. GO to PINPOINT TEST B .
P1783 TFT Transmission over temperature condition indicated Transmission fluid temperature exceeded 127°C (270°F). Increase in EPC pressure. GO to PINPOINT TEST B .
P1718 TFT, wiring, PCM TFT continually reading hot TFT sensor in range high failure. Firm shift feel. Substitute ECT for TFT. GO to PINPOINT TEST B .
P0740 TCC, wiring, PCM TCC electrical failure TCC circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostics. Short circuit, engine stalls in 2nd ((D), manual 2 range) at low speeds with brake applied. Open circuit, torque converter clutch never engages. May flash TCIL. GO to PINPOINT TEST A .
P1740 TCC TCC malfunction Mechanical failure of the solenoid detected. Failed on - Engine stalls in 2nd (O/D, Manual 2 ranges) at low idle speeds with brake applied. Failed off - Torque Converter never applies. GO to PINPOINT TEST G .
P1741 May also be generated by some other non-electric transmission hardware system. TCC, internal components Excessive torque converter clutch engagement error Excessive variations in slip (engine speed surge) across the torque converter clutch. Engine rpm oscillation is present in 3rd gear. GO to PINPOINT TEST A .
P1742 TCC, internal components TCC solenoid failed on TCC solenoid has failed on by electric, mechanical or hydraulic concern. Harsh shifts. GO to PINPOINT TEST A .
P1743 TCC, internal components TCC solenoid failed on TCC solenoid has failed on by electric, mechanical or hydraulic concern. Harsh shifts. GO to PINPOINT TEST A .
P1744 TCC The PCM picked up an excessive amount of TCC slippage during normal vehicle operation. TCC slippage/erratic or no torque converter clutch operation. Refer to DIAGNOSIS BY SYMPTOM .
P1746 Output circuit check, generated only by electrical symptoms, P0960 EPC, wiring, PCM EPC solenoid open circuit Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Open circuit causes maximum EPC pressure, harsh engagements and shifts. GO to PINPOINT TEST D .
P1747 Output circuit check, generated only by electrical symptoms. P0962 EPC, wiring, PCM EPC solenoid circuit failure, shorted circuit or output driver Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Short circuit causes minimum EPC pressure (minimum capacity) and limits engine torque (alternate firm). GO to PINPOINT TEST D .
P1760 EPC, wiring, PCM EPC solenoid circuit failure, shorted circuit or output driver PCM detected a loss of EPC during operation. Unexpected reduction in engine torque. GO to PINPOINT TEST D .
P0963 EPC solenoid EPC solenoid short to power (Vbat) circuit failure Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Maximum EPC pressure, harsh engagements and shifts. GO to PINPOINT TEST D .
P0748 May also be generated by some other non-electric transmission hardware system. EPC solenoid EPC solenoid circuit failure Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Short circuit results in minimum EPC pressure (minimum capacity) and limits engine torque (alternate firm). Not all gears present. Open circuit: maximum PC A pressure, harsh engagements and shifts. GO to PINPOINT TEST D .
P1728 Trans Transmission slip error The PCM has detected an excessive amount of slippage during normal operation. Transmission slippage erratic or no torque converter clutch operation. Refer to DIAGNOSIS BY SYMPTOM .