Component Testing Procedure
POWER WINDOW SWITCH, RH SIDE FRONT COMPONENT TESTING
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Window regulator circuit, Up | 5 and 3 | Up | Closed circuit |
| Window regulator circuit, Down | 2 and 3 | Down | Closed circuit |
| Master window control switch | 5 and 6 | Up | Closed circuit |
| 2 and 1 | Down | Closed circuit |