Using Output State Control (OSC) and Monitoring PIDs

To confirm that the OSC value was sent by the scan tool and the PCM has accepted the OSC command, a corresponding PID for each OSC parameter must be monitored. After SENDING the OSC value, the corresponding PID value should be the same as the OSC value that was sent. Additional PIDs are listed that may be monitored to help the technician accurately diagnose the transaxle.

The following is a list of OSC parameters and their corresponding PIDs:

OSC Parameter Corresponding PID Additional PIDs
HRSH_SHFT HRSH_SHFT  
LINEDSD LINEDSD PCA, PCA AMP, PCA_F
TCC_OSC TCC_OSC TCCRAT, TCCMCMD, TSLIP
GEAR_OSC GEAR_OSC SHFT_TYP, GEAR, TRANRAT
SSA_AMP SSA_AMP SSPCA, SSPCA_F
SSB_AMP SSB_AMP SSPCB, SSPCB_F
SSC_AMP SSC_AMP SSPCC, SSPCC_F
SSD_AMP SSD_AMP SSPCD, SSPCD_F
PCA AMP PCA AMP PCA_F
TCC AMP TCC AMP TCCPC, TCCPC_F
SSA/SS1 SSA/SS1 SSA/SS1_F