LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2007 >> Freestar Base, 4.2 2 >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> In-Vehicle Servicing >> Digital Transmission Range (TR) Sensor >> Installation
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Digital Transmission Range (TR) Sensor: Installation

  1. Install the digital TR sensor and loosely install the bolts.
  2. Fig 1: Identifying Digital TR Sensor Bolts
    GF0033405Courtesy of FORD MOTOR CO.
  3. Using the special tool, align the digital TR sensor and tighten the bolts.
    • Tighten to 11 Nm (8 lb-ft).
  4. Fig 2: Aligning Digital TR Sensor Using Special Tool (307-351)
    GF0020155Courtesy of FORD MOTOR CO.
  5. Install the manual control lever and cable
    1. Install the manual lever and nut.
      • Tighten to 13 Nm (10 lb-ft).
  6. Fig 3: Locating Manual Control Lever And Nut
    G04005358Courtesy of FORD MOTOR CO.
  7. Connect the shift cable back onto the manual control lever.
  8. Fig 4: Shift Cable At Manual Control Lever
    GF0033404Courtesy of FORD MOTOR CO.
  9. Install the air filter assembly.
  10. Fig 5: Locating Air Filter Assembly
    GF0020151Courtesy of FORD MOTOR CO.
  11. Install the engine air cleaner lid.
  12. Fig 6: Locating Engine Air Cleaner Lid
    GF0020150Courtesy of FORD MOTOR CO.
  13. Reconnect the mass air flow (MAF) sensor and the breather tubes.
  14. Fig 7: Locating Mass Air Flow (MAF) Sensor And Breather Tubes
    GF0019965Courtesy of FORD MOTOR CO.
  15. Verify that the shift cable is correctly adjusted. For additional information, refer to AUTOMATIC TRANSAXLE/TRANSMISSION EXTERNAL CONTROLS article.