LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2008 >> Edge Limited, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Reference Values (Except Diesel & Hybrid) >> 3.0L 4V Fusion/Milan >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
APP1 B25 4 4 3.9 3.7 DCV
APP2 B26 1.5 1.5 1.6 1.8 DCV
APP3 B27 1 1 1.1 1.2 DCV
FPM B30 OFF ON ON ON ON/OFF
MAF B41 0 0.68 1.27 1.83 DCV
IAT B43 1.75/120 (K) 2.02/109 (K) 3.16/64 (K) 3.22/63 (K) DCV/DEG F
FTP B44 2.6/-0 2.6/-0 2.57/-0.01 2.5/-0.03 DCV/PSI
BPA B47 OFF ON (E) OFF OFF ON/OFF
A/CT B53 3.1/73.4 3.05/75.2 (A) 4/39 3.92/42 DCV/DEG F
ACP_PRESS B63 2.36/235 2.39/239 2.24/223 2.12/210 DCV/PSI
PSP B65 LOW HIGH (I) LOW LOW HIGH/LOW
O2S12 E3 (L) (D) (D) (D) DCV
O2S22 E4 0.1 (D) (D) (D) DCV
ECT E18 0.45/210 0.44/210 0.53/199 0.57/196 DCV/DEG F
HTRCM12 E23 617 617 617 617 mA
HTRCM22 E24 605 605 605 605 mA
GENMON E26 0 35.16 28.13 25 %
O2S11 E28 (L) switching (C) switching (C) switching (C) DCV/
RICH-LEAN
O2S21 E29 0 switching (C) switching (C) switching (C) DCV/
RICH-LEAN
BOO E46 OFF ON (E) OFF OFF ON/OFF
KNOCK 1 E49 654 650 1366 1621 N/A
TP2 E60 1.22/24.31 0.74/14.9 0.99/19.61 1.3/25.88 DCV/%
TP1 E61 4.05/18.82 4.29/13.73 4.17/16.47 4/19.61 DCV/%
MAP E62 4.02/14.35 (W) 1.28/4.49 (W) 2.37/8.55 (W) 1.86/6.67 (W) DCV/PSI
HTRCM11 E69 1.62 1.62 1.62 1.62 AMPS
HTRCM21 E70 1.58 1.58 1.58 1.58 AMPS
APP PID 0 0 4 11 %
BARO PID 14.48/157.4 14.48/157.4 14.48/157.4 14.48/157.4 PSI/HZ
B+ PID VBAT VBAT VBAT VBAT DCV
CPP/PNP PID NEUTRAL NEUTRAL DRIVE DRIVE NEUTRAL/
DRIVE
DECHOKE PID YES NO NO NO YES/NO
ETC_ACT PID 8 2.62 6.45 8.93 DEG
ETC_DSD PID 7.79 2.62 6.45 9.08 DEG
FLI PID 73.5 (H) 73 (H) 90 (H) 83 (H) %
LOAD PID 65 (L) 17 19 25 %
MISFIRE PID NO NO NO NO ON/OFF
O2BANK1 PID VARIES VARIES VARIES VARIES RICH/LEAN
O2BANK2 PID VARIES VARIES VARIES VARIES RICH/LEAN
RPM PID 0 766 1600 1700 RPM
VSS PID 0 0 30 55 MPH
Actuators/ Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVMV B4 0/OFF 0/OFF 480/
VARYING
962/
VARYING
mA/OFF-
VARYING
FANVAR B8 0 38 32 71 %
FP B62 OFF ON ON ON ON/OFF
WAC/ACCR B64 OFF ON OFF OFF ON/OFF
PCVHC E2 0 0 0 0 %
SPKDUR_6 E10 0 2.18 2.12 1.15 ms
SPKDUR_5 E11 0 2.06 1.87 1.09 ms
SPKDUR_4 E12 0 2.37 2.15 1.43 ms
GENCMD E13 3.79 0 (Q) 0 (Q) 0 (Q) %
SPKDUR_3 E15 0 1.71 2.12 0.875 ms
SPKDUR_2 E16 0 2.28 1.71 1 ms
SPKDUR_1 E17 0 2.4 2 1.46 ms
HTR12 E23 OFF ON ON ON ON/OFF
HTR22 E24 OFF ON ON ON ON/OFF
VCTDC E67 0 0 41.7 39.5 %
VCTDC2 E68 0 0 43.3 33.7 %
HTR11 E69 ON (O) ON ON ON ON/OFF
HTR21 E70 ON (O) ON ON ON ON/OFF
EGR_EVAL PID YES YES YES YES YES/NO
EVAP020C PID NO NO NO NO YES/NO
EVAP020D PID ALLOW ALLOW ALLOW ALLOW ALLOW/
DISALLOW
EVAP020R PID READY READY READY READY READY/NOT READY
EVAPCV PID 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID NO NO NO NO YES/NO
EVAP_EVAL PID NO NO NO NO YES/NO
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/
CLOSED LOOP
LONGFT1 PID (L) (-)20-(+)20 (-)20-(+)20 (-)20-(+)20 %
LONGFT2 PID (L) (-)20-(+)20 (-)20-(+)20 (-)20-(+)20 %
MIL PID OFF OFF OFF OFF ON/OFF
SHRTFT1 PID (L) (-)10-(+)10 (-)10-(+)10 (-)10-(+)10 %
SHRTFT2 PID (L) (-)10-(+)10 (-)10-(+)10 (-)10-(+)10 %
SPARKADV PID 10 14 36 40 DEG
VCTADV PID 0 -0.37 10.8 32 DEG
VCTADV2 PID 0 -1 8 33.7 DEG
VCTADVERR PID 0 -0.68 0.81 1.12 DEG
VCTADVERR2 PID 0 1 1.56 -0.43 DEG
Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR B51/52 VBAT VBAT VBAT VBAT DCV