Removal And Installation
NOTE:
When installing a new stability control sensor cluster, the ABS module must be calibrated. Follow the scan tool directions for the calibration procedures.
- Remove the front floor console. For additional information refer to INSTRUMENT PANEL AND CONSOLE article.
- Disconnect the stability control sensor cluster electrical connector.
- Remove the stability control sensor cluster electrical harness retainers and position aside.
- Remove the 2 stability control sensor cluster bracket bolts and the stability control sensor cluster.
- To install, tighten to 12 Nm (106 lb-in).
- To install, reverse the removal procedure.