Control System Outputs

The EMTC system has 4 system outputs.

Blower Motor Resistor 

The blower motor switch varies the blower motor ground circuit resistance by adding or bypassing series resistance in the blower motor resistor. Increased resistance will lower the blower motor speed, and lowered resistance will increase blower motor speed. When the blower motor is in the HI position, the blower motor resistor is bypassed.

The blower motor resistor is located on the heater core and evaporator core housing.

Temperature Blend Door Actuator 

The temperature blend door actuator moves the temperature blend door on command from the HVAC module.

The temperature blend door actuator contains a reversible electric motor and a potentiometer. The potentiometer circuit consists of a 5-volt reference signal connected to one end of a variable resistor, and a signal ground connected to the other. A signal return circuit is connected to a contact wiper, which is driven along the variable resistor by the actuator shaft. The signal returned to the HVAC module from the contact wiper indicates the position of the temperature blend door. The HVAC module drives the actuator motor in whichever direction is necessary to make the actuator contact wiper voltage agree with the expected HVAC module contact wiper voltage value.

Airflow Mode Door Actuator 

The airflow mode door actuator uses a cam and lever assembly to position the airflow mode doors on command from the HVAC module. The mode door actuator contains a reversible electric motor and potentiometer. The potentiometer allows the HVAC module to monitor the position of the airflow mode doors. The potentiometer circuit consists of a 5-volt reference signal connected to one end of a variable resistor, and a signal ground connected to the other. A signal return circuit is connected to a contact wiper, which is driven along the variable resistor by the actuator shaft. The signal returned to the HVAC module from the contact wiper indicates the position of the airflow mode doors.

Air Inlet Mode Door Actuator 

The air inlet mode door actuator moves the air inlet door between the fresh and RECIRC positions on command from the HVAC module. The air inlet mode door actuator is driven to, and will automatically stop at, the full RECIRC or full fresh air inlet position and does not require a potentiometer circuit to monitor its position.



The EATC system has 4 control system outputs.

Blower Motor Speed Control 

The blower motor speed control controls the blower motor speed by converting low power signals from the HVAC module to a high current, variable ground feed for the blower motor. A delay function is used to provide a gradual increase or decrease in blower motor speed under all conditions.

Temperature Blend Door Actuators 

The dual-zone EATC system uses 2 temperature blend door actuators to control 2 separate temperature blend doors. The temperature blend doors independently vary the LH side and RH side temperature settings, as desired. The temperature blend door actuators each contain a reversible electric motor and a potentiometer. The potentiometer circuit consists of a 5-volt reference signal connected to one end of a variable resistor, and a signal ground connected to the other. A signal return circuit is connected to a contact wiper, which is driven along the variable resistor by the actuator shaft. The signal returned to the HVAC module from the contact wiper indicates the position of the temperature blend door. The HVAC module drives the actuator motor in whichever direction is necessary to make the actuator contact wiper voltage agree with the expected HVAC module contact wiper voltage value.

Airflow Mode Door Actuator 

The airflow mode door actuator uses a cam and lever assembly to position the airflow mode doors on command from the HVAC module. The mode door actuator contains a reversible electric motor and potentiometer. The potentiometer allows the HVAC module to monitor the position of the airflow mode doors. The potentiometer circuit consists of a 5-volt reference signal connected to one end of a variable resistor, and a signal ground connected to the other. A signal return circuit is connected to a contact wiper, which is driven along the variable resistor by the actuator shaft. The signal returned to the HVAC module from the contact wiper indicates the position of the airflow mode doors.

Air Inlet Mode Door Actuator 

The air inlet mode door actuator moves the air inlet door between the fresh and RECIRC positions on command from the HVAC module. The air inlet mode door actuator is driven to, and will automatically stop at, the full RECIRC or full fresh air inlet position and does not require a potentiometer circuit to monitor its position.