Mechatronic Assembly: Disassembly
NOTE:
Do not touch the electrical connector pins or the exposed solenoid tabs on the Transmission Control Module (TCM). An electrostatic discharge may occur and may cause damage to the TCM
/mechatronic assembly.
NOTE:
Make an identifying mark on each solenoid and the corresponding bore for correct assembly.
NOTE:
Solenoids may visually appear the same but their designs/functions are different. Caution must be taken not to assemble the mechatronic assembly incorrectly. Incorrect solenoid installation will result in poor transmission shift quality.
NOTE:
Note where the 8 check balls, 6 solenoid dampers, 2 internal valves and springs and 2 internal filters are located for reassembly.
Mechatronic assembly upper half
- Make an identifying mark on each solenoid and the corresponding bore for correct assembly.
- Remove the 6 long bolts from the Transmission Control Module (TCM) unit.
- Carefully separate the TCM
from the mechatronic assembly.
- TCM
- Mechatronic assembly
- Remove 19 short bolts from the mechatronic assembly.
- Separate the lower half of the mechatronic assembly from the upper half of the mechatronic assembly.
- Remove and discard the separator plate.
- Remove the solenoid dampers, check balls, converter drain back valve and filter screens from the mechatronic assembly. Note the location for assembly. Refer to Fig 6.
- Solenoid dampers
- Check balls
- Converter drain back valve
- Small screen
- Big screen
- Remove the clips, caps, valves and springs from each bore of the mechatronic assembly. Note the location and order for assembly. Refer to Fig 7.
- Using clean mineral spirits, clean the upper half of the mechatronic assembly.
Mechatronic assembly lower half
- Remove the 8 solenoid bracket bolts and the solenoid bracket.
- Remove the solenoids.
- Remove the clips, caps, valves and springs from each bore of the mechatronic assembly. Note the location and order for assembly. Refer to Fig 10.
- Using clean mineral spirits, clean the lower half of the mechatronic assembly.