Removal And Installation: Generator: Removal
- Disconnect the battery. For additional information, refer to BATTERY, MOUNTING AND CABLES .
- Position the generator protective cover aside, remove the B+ nut and position the B+ terminal aside.
- Disconnect the generator electrical connector and position the harness aside.
- Remove the cooling fan assembly. For additional information, refer to ENGINE COOLING .
- Rotate the accessory drive belt tensioner and remove the accessory drive belt from the generator.
- Remove the upper generator nut and stud.
- Loosen the lower generator bolt.
- Remove the generator.