Solenoid Operation Chart
SOLENOID OPERATION CHART
| Base Selector Lever Position | PCM Commanded Gear | Shift Solenoid | TCC (VFS) NL | ||||
|---|---|---|---|---|---|---|---|
| SSA (VFS) NL (CB 1,2,3,4) | SSB (VFS) NH (3,5,R) | SSC (VFS) NL (CB 2,6) | SSD (VFS) NH (CB L,R/C 4,5,6) | SSE (On/Off) NC | |||
| P | P | Off | On | Off | Off | On | Off |
| R | R | Off | Off | Off | Off | On | Off |
| N | N | Off | On | Off | Offa | Ona | Off |
| D | 1 | On | On | Off | Offb | Onc | Off |
| 2 | On | On | On | On | Off | Off | |
| 3 | On | Off | Off | On | Off | Off | |
| 4 | On | On | Off | Off | Off | On/Off | |
| 5 | Off | Off | Off | Off | Off | On/Off | |
| 6 | Off | On | On | Off | Off | On/Off | |
| L | L | On | On | Off | Offb | Onc | Off |
| CB = Clutch brake NC = Normally closed NH = Normally high NL = Normally low |
|||||||
a Solenoid state will change if vehicle is moving forward with the selector lever in the NEUTRAL position.
b Turns on above 10 km/h (6 mph).
c Turns off above 10 km/h (6 mph).