Removal and Installation
NOTE:
The radial arm adapter is a serviceable item. Do not replace the generator if the radial arm adapter is the only concern.
- Disconnect the battery. For additional information, refer to BATTERY, MOUNTING AND CABLES .
- Remove the cooling fan. For additional information, refer to ENGINE COOLING .
- Rotate the accessory drive belt tensioner counterclockwise and position the accessory drive belt aside.
- Position the generator B+ terminal protective cover aside, remove the nut and position the generator B+ terminal aside.
- To install, tighten to 17 Nm (150 lb-in).
- Disconnect the generator electrical connector.
- Detach the pin-type retainer and wiring harness.
- Remove the generator stud nut.
- To install, tighten to 47 Nm (35 lb-ft).
- Remove the generator stud.
- To install, tighten to 8 Nm (71 lb-in).
- Remove the RH fender splash shield. For additional information, refer to FRONT END BODY PANELS .
- Loosen the generator bolt and remove the generator.
- To install, tighten to 47 Nm (35 lb-ft).
- To install, reverse the removal procedure.