Network Message Chart

MODULE NETWORK INPUT MESSAGES REMOTE FUNCTION ACTUATOR - NETWORK MESSAGE CHART

Broadcast Message Originating Module Message Purpose
Remote start command Tire Pressure Monitor Module (TPM) via Local Interconnect Network (LIN) Provides the Remote Function Actuator (RFA) with the Intelligent Access (IA) key command for a remote start.
MODULE NETWORK INPUT MESSAGES BODY CONTROL MODULE - NETWORK MESSAGE CHART

Broadcast Message Originating Module Message Purpose
Remote Keyless Entry (RKE) data (with Intelligent Access (IA)) Remote Function Actuator (RFA) module Provide the Body Control Module (BCM) with the correct Intelligent Access (IA) key data. Provides a request to the Body Control Module (BCM) for starting per customer remote start request.
MODULE NETWORK INPUT MESSAGES POWERTRAIN CONTROL MODULE - NETWORK MESSAGE CHART

Broadcast Message Originating Module Message Purpose
Starter crank request Body Control Module (BCM) Provides the Powertrain Control Module (PCM) with ignition, hood input status and a request to crank and start the engine during a remote start event.
Remote start request Body Control Module (BCM) Provides the Powertrain Control Module (PCM) with a request for remote start.