GENERAL SPECIFICATIONS

Item Specification
Generator (3.7L) 
Generator pulley ratio 2.69:1 (automatic transmission), 2.98:1 (manual transmission)
Rating 83 amp @ 650 rpm (min) to 156 amps @ 6,000 rpm (max)
Voltage regulator type Electronic internal with generator
Generator (5.0L) 
Generator pulley ratio 2.69:1 (automatic transmission), 2.98:1 (manual transmission)
Rating (5.0L) 96 amp @ 650 rpm (min) to 156 amps @ 6,000 rpm (max)
Voltage regulator type Electronic internal with generator
Generator (5.4L) 
Generator pulley ratio 2.71:1
Rating 94 amp @ 700 rpm (min) to 156 amps @ 6,000 rpm (max)
Voltage regulator type Electronic internal with generator