LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2011 >> Taurus SE >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Reference Values (Except Diesel & Hybrid) >> Typical Diagnostic Reference Values >> 4.0L Ranger
April 5, 2026: LEMON Manuals is launched! Read the announcement.

4.0L Ranger

Fig 1: 170 Pin PCM Harness Connectors - 4.0L Ranger
G06054079Courtesy of FORD MOTOR CO.

Typical Diagnostic Reference Values 

SENSORS - 4.0L RANGER

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FTP B3 2.6/0 2.6/0 2.6/0 2.6/0 VOLTS/PSI
FTP_H2O B3 0 0 0 0 in-H2 O
BOO B8 OFF OFF OFF OFF ON/OFF
FPM B21 OFF ON ON ON ON/OFF
TCS B29 NOT DEPRESSED NOT DEPRESSED NOT DEPRESSED NOT DEPRESSED DEPRESSED/NOT DEPRESSED
CPP/PNP B33 NEUTRAL NEUTRAL DRIVE DRIVE NEUTRAL/DRIVE
ECT E18 0.4-1/93.3-71.1 (200-160) 0.4-1/93.3-71.1 (200-160) 0.4-1/93.3-71.1 (200-160) 0.4-1/93.3-71.1 (200-160) VOLTS/DEG C (DEG F)
DPFEGR E21 0.25-1.30 0.25-1.30 0.25-4.65 0.25-4.65 VOLTS
IAT E22 1.7-3.5/48.8-10 (120-50) 1.7-3.5/48.8-10 (120-50) 1.7-3.5/48.8-10 (120-50) 1.7-3.5/48.8-10 (120-50) VOLTS/DEG C (DEG F)
MAF E25 0 0.7-0.9 1.2-1.6 1.6-2.1 VOLTS
O2S11 E28 (I) switching (C) switching (C) switching (C) VOLTS/RICH-LEAN
O2S21 E29 (I) switching (C) switching (C) switching (C) VOLTS/RICH-LEAN
KNOCK 1 E49 16380 196 173 212 N/A
TP E61 1.05/CT 1.05/CT 1.21/PT 1.29/PT VOLTS/CT/PT/WOT
OSS T3 0 0 1261 2294 RPM
TSS T15 0 775 926 1716 RPM
TR2 T17 CLOSED CLOSED OPEN OPEN OPEN/CLOSED
O2S12 T24 (I) (D) (D) (D) VOLTS
O2S22 T25 (I) (D) (D) (D) VOLTS
TFT T29 0.5-2/98.8-43.3 (210-110) 0.5-2/98.8-43.3 (210-110) 0.5-2/98.8-43.3 (210-110) 0.5-2/98.8-43.3 (210-110) VOLTS/DEG C (DEG F)
ACCS PID OFF ON (A) OFF OFF ON/OFF
B+ PID VBAT VBAT VBAT VBAT VOLTS
BARO PID 14.18/155.1 14.18/155.1 14.18/155.1 14.18/155.1 PSI/Hz
DECHOKE PID YES NO NO NO YES/NO
FCIL PID OFF OFF OFF OFF ON/OFF
FLI PID 50 (H) 50 (H) 50 (H) 50 (H) %
GEAR PID 1 1 4 5 GEAR
LOAD PID (I) 17-28 19-26 30-40 %
O2BANK1 PID VARIES VARIES VARIES VARIES RICH/LEAN
O2BANK2 PID VARIES VARIES VARIES VARIES RICH/LEAN
RPM PID 0 750 1300-1350 1780 RPM
TORQUE PID 238.7 10.85 8.13 179 Nm
TPCT PID 1.05 1.05 1.05 1.05 VOLTS
TR PID P P OD OD MODE
TSS/ISS PID 0 750 990 1720 RPM
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
ACTUATORS - 4.0L RANGER

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FP B12 OFF ON ON ON ON/OFF
PCVHC E3 0 0 0 0 %
EVMV E6 0 0 500-900 (F) 500-900 (F) mA
IAC E33 0 35 35-41 (I) 57-68 (I) %
EGRVR E63 0 0 VARIES VARIES %
HTR11 E69 OFF ON ON ON ON/OFF
HTRCM11 E69 539 539 535 535 mA
HTR21 E70 OFF ON ON ON ON/OFF
HTRCM21 E70 504 504 500 500 mA
TCC T46 0/OFF 0/OFF 0/OFF 100/ENGAGED %/OFF-ENGAGED
HTR12 T47 OFF ON ON ON ON/OFF
HTRCM12 T47 938 938 906 906 mA
HTR22 T48 OFF ON ON ON ON/OFF
HTRCM22 T48 922 922 945 945 mA
EGR_EVAL PID NO NO NO NO YES/NO
EVAP020C PID NO NO NO NO YES/NO
EVAP020D PID ALLOW ALLOW ALLOW ALLOW ALLOW/DISALLOW
EVAP020R PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EVAPCV PID 0/OFF 0/OFF 0/OFF 0/OFF %/ON/OFF
EVAPSOAK PID YES YES NO NO YES/NO
EVAP_EVAL PID NO NO NO NO YES/NO
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MIL PID OFF OFF OFF OFF ON/OFF
SHRTFT1 PID 0 -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID 0 -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 0 20-25 30-35 30-35 DEG
OTHERS - 4.0L RANGER

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR B35/B36 VBAT VBAT VBAT VBAT VOLTS
VREF B40/T40 5 5 5 5 VOLTS