Escape (Hybrid)
PCM DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Description | Action |
|---|---|---|
| P0532 | A/C Pressure Refrigerant Sensor A Circuit Low | GO to PINPOINT TEST A . |
| P0533 | A/C Refrigerant Pressure Sensor A Circuit High | GO to PINPOINT TEST A . |
| P2600 | Coolant Pump A Control Circuit/Open | GO to PINPOINT TEST B . |
| All Other DTCs | - | REFER to INTRODUCTION -- ESCAPE HYBRID article. |
AIR CONDITIONING COMPRESSOR MODULE (ACCM) DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Description | Action |
|---|---|---|
| P0AFA:16 | Hybrid Battery System Voltage Low: Circuit Voltage Below Threshold | GO to PINPOINT TEST J . |
| P0AFB:17 | Hybrid Battery System Voltage High: Circuit Voltage Above Threshold | GO to PINPOINT TEST J . |
| B11EE:19 | A/C Compressor: Current Above Threshold | INSTALL a new electric A/C compressor. REFER to CLIMATE CONTROL article. TEST the system for normal operation. |
| B11EE:49 | A/C Compressor: Internal Electronic Failure | INSTALL a new electric A/C compressor. REFER to CLIMATE CONTROL article. TEST the system for normal operation. |
| B11EE:4B | A/C Compressor: Over Temperature | VERIFY the refrigerant charge level. REFER to SPECIFICATIONS . If the charge level is low, RECHARGE the system, CLEAR the DTCs and REPEAT the self-test. TEST the system for normal operation. If the DTC returns, INSTALL a new electric A/C compressor. REFER to CLIMATE CONTROL article. TEST the system for normal operation. |
| U0100:00 | Lost Communication With ECM/PCM "A": No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the ECM/PCM "A". |
| U0155:00 | Lost Communication With Instrument Panel Cluster (IPC) Module: No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the IPC module. |
| U0401:68 | Invalid Data Received From ECM/PCM "A": Event Information | This DTC can set due to a fault in the PCM or because the PCM is unable to communicate over the Controller Area Network (CAN) bus. CARRY OUT a self-test of the PCM. If the scan tool indicates that the PCM is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If PCM DTCs are present, REFER to the INTRODUCTION -- ESCAPE HYBRID article. |
| U0423:68 | Invalid Data Received From Instrument Panel Cluster Control Module: Event Information | This DTC can set due to a fault in the Instrument Panel Cluster (IPC) or because the IPC is unable to communicate over the CAN bus. CARRY OUT a self-test of the IPC. If the scan tool indicates that the IPC is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If IPC DTCs are present, REFER to INSTRUMENTATION, MESSAGE CENTER, AND WARNING CHIMES article to diagnose the IPC system fault. |
| U3000:49 | Control Module: Internal Electronic Failure | INSTALL a new electric A/C compressor. REFER to CLIMATE CONTROL article. TEST the system for normal operation. |
HVAC MODULE DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Description | Action |
|---|---|---|
| B1081:07 | Left Temperature Damper Motor: Mechanical Failure | GO to PINPOINT TEST Q . |
| B1081:11 | Left Temperature Damper Motor: Circuit Short to Ground | GO to PINPOINT TEST Q . |
| B1081:12 | Left Temperature Damper Motor: Circuit Short to Battery | GO to PINPOINT TEST Q . |
| B1081:13 | Left Temperature Damper Motor: Circuit Open | GO to PINPOINT TEST Q . |
| B1082:07 | Right Temperature Damper Motor: Mechanical Failure | GO to PINPOINT TEST Q . |
| B1082:11 | Right Temperature Damper Motor: Circuit Short to Ground | GO to PINPOINT TEST Q . |
| B1082:12 | Right Temperature Damper Motor: Circuit Short to Battery | GO to PINPOINT TEST Q . |
| B1082:13 | Right Temperature Damper Motor: Circuit Open | GO to PINPOINT TEST Q . |
| B1083:07 | Recirculation Damper Motor: Mechanical Failure | GO to PINPOINT TEST L . |
| B1083:11 | Recirculation Damper Motor: Circuit Short to Ground | GO to PINPOINT TEST L . |
| B1083:12 | Recirculation Damper Motor: Circuit Short to Battery | GO to PINPOINT TEST L . |
| B1083:13 | Recirculation Damper Motor: Circuit Open | GO to PINPOINT TEST L . |
| B1086:07 | Air Distribution Damper Motor: Mechanical Failures | GO to PINPOINT TEST M . |
| B1086:11 | Air Distribution Damper Motor: Circuit Short to Ground | GO to PINPOINT TEST M . |
| B1086:12 | Air Distribution Damper Motor: Circuit Short to Battery | GO to PINPOINT TEST M . |
| B1086:13 | Air Distribution Damper Motor: Circuit Open | GO to PINPOINT TEST M . |
| B10AF:12 | Blower Fan Relay: Circuit Short to Battery | GO to PINPOINT TEST R . |
| B10AF:14 | Blower Fan Relay: Circuit Short to Ground or Open | GO to PINPOINT TEST R . |
| B10B8:00 | Push Buttons: No Sub Type Information | Button held too long may set DTC. ATTEMPT to clean buttons. CLEAR the DTCs. REPEAT the self-test. If code returns, INSTALL a new Front Controls Interface Module (FCIM). |
| B10B9:12 | Blower Control: Circuit Short to Battery | GO to PINPOINT TEST S . |
| B10B9:14 | Blower Control: Circuit Short to Ground or Open | GO to PINPOINT TEST R . |
| B11E5:11 | Left HVAC Damper Position Sensor: Circuit Short to Ground | GO to PINPOINT TEST Q . |
| B11E5:15 | Left HVAC Damper Position Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST Q . |
| B11E6:11 | Right HVAC Damper Position Sensor: Circuit Short to Ground | GO to PINPOINT TEST Q . |
| B11E6:15 | Right HVAC Damper Position Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST Q . |
| B11E7:11 | Air Distribution Damper Position Sensor: Circuit Short to Ground | GO to PINPOINT TEST M . |
| B11E7:15 | Air Distribution Damper Position Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST M . |
| B11F0:11 | Air Intake Damper Position Sensor: Circuit Short to Ground | GO to PINPOINT TEST L . |
| B11F0:15 | Air Intake Damper Position Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST L . |
| B1A61:11 | Cabin Temperature Sensor: Circuit Short to Ground GO to PINPOINT TEST D . B1A61:15 Cabin Temperature Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST D . |
| B1A63:11 | Right Solar Sensor: Circuit Short to Ground | GO to PINPOINT TEST F . |
| B1A63:15 | Right Solar Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST F . |
| B1A64:11 | Left Solar Sensor: Circuit Short to Ground | GO to PINPOINT TEST F . |
| B1A64:15 | Left Solar Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST F . |
| B1A68:11 | Ambient Temperature Sensor: Circuit Short to Ground | GO to PINPOINT TEST E . |
| B1A68:15 | Ambient Temperature Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST E . |
| B1A69:11 | Humidity Sensor: Circuit Short to Ground | GO to PINPOINT TEST G . |
| B1A69:15 | Humidity Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST G . |
| B1B71:11 | Evaporator Temperature Sensor: Circuit Short to Ground | GO to PINPOINT TEST H . |
| B1B71:15 | Evaporator Temperature Sensor: Circuit Short to Battery or Open | GO to PINPOINT TEST H . |
| C1B14:11 | Sensor Supply Voltage A: Circuit Short to Ground | GO to PINPOINT TEST C . |
| C1B14:12 | Sensor Supply Voltage A: Circuit Short to Battery | GO to PINPOINT TEST C . |
| U0140:00 | Lost Communication With Body Control Module: No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the Smart Junction Box (SJB). |
| U0155:00 | Lost Communication With Instrument Panel Cluster (IPC) Module: No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the IPC module. |
| U0163:00 | Lost Communication With Navigation Control Module: No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the Audio Control Module (ACM). |
| U0256:00 | Lost Communication With Front Controls Interface Module (FCIM) "A": No Sub Type Information | REFER to MODULE COMMUNICATIONS NETWORK article to diagnose lost communication with the FCIM. |
| U0422:68 | Invalid Data Received From Body Control Module: Event Information | This DTC can set due to a fault in the SJB or because the SJB is unable to communicate over the Controller Area Network (CAN) bus. CARRY OUT a self-test of the SJB. If the scan tool indicates that the SJB is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If SJB DTCs are present, REFER to MULTIFUNCTION ELECTRONIC MODULES article. |
| U0423:68 | Invalid Data Received From Instrument Panel Cluster Control Module: Event Information | This DTC can set due to a fault in the IPC or because the IPC is unable to communicate over the CAN bus. CARRY OUT a self-test of the IPC. If the scan tool indicates that the IPC is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If IPC DTCs are present, REFER to INSTRUMENTATION, MESSAGE CENTER, AND WARNING CHIMES article to diagnose the IPC system fault. |
| U0464:68 | Invalid Data Received From Navigation Control Module: Event Information | This DTC can set due to a fault in the Audio Control Module (ACM) or because the ACM is unable to communicate over the CAN bus. CARRY OUT a self-test of the ACM. If the scan tool indicates that the ACM is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If ACM DTCs are present, REFER to INFORMATION AND ENTERTAINMENT SYSTEMS article to diagnose the ACM system fault. |
| U0557:68 | Invalid Data Received From Front Controls Interface Module (FCIM) "A": Event Information | This DTC can set due to a fault in the FCIM or because the FCIM is unable to communicate over the CAN bus. CARRY OUT a self-test of the FCIM. If the scan tool indicates that the FCIM is not responding, REFER to MODULE COMMUNICATIONS NETWORK article to diagnose the network communication concern. If FCIM DTCs are present, REFER to INFORMATION AND ENTERTAINMENT SYSTEMS article to diagnose the FCIM fault. |
| U1000:00 | Solid State Driver Protection Activated-Driver Disabled: No Sub Type Information | INSTALL a new HVAC module. REFER to CLIMATE CONTROL article. |
| U2100:00 | Initial Configuration Not Complete: No Sub Type Information | INSTALL a new HVAC module. REFER to CLIMATE CONTROL article. |
| U3000:41 | Control Module: General Checksum Failure | INSTALL a new HVAC module. REFER to CLIMATE CONTROL article. |
| U3000:49 | Control Module: Internal Electronic Failure | INSTALL a new HVAC module. REFER to CLIMATE CONTROL article. |
| U3002:62 | Vehicle Identification Number: Signal Compare Failure | INSTALL a new HVAC module. REFER to CLIMATE CONTROL article. |
| U3003:16 | Battery Voltage: Circuit Voltage Below Threshold | GO to PINPOINT TEST I . |
| U3003:17 | Battery Voltage: Circuit Voltage Above Threshold | GO to PINPOINT TEST I . |
| All Other DTCs | - | REFER to the Master DTC Chart in MULTIFUNCTION ELECTRONIC MODULES article. |