Normal Operation
The operating voltage required to operate the ABS module, hydraulic pump and isolation valves is in a range between 10 and 17 volts.
Fused battery voltage is supplied by the Battery Junction Box (BJB). Fused ignition voltage is also supplied by the BJB.
- DTC B1676 (Battery Pack Voltage Out of Range) - If the voltage to the ABS module is above 16 volts or below 10 volts, DTC B1676 is set.
This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Wiring, terminals or connectors
- Charging system/vehicle battery
- ABS module