Component testing procedure
COMPONENT TESTING PROCEDURE CHART
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Power Checks before any other tests | 2 (352A) and 1 (C352A) | at rest | Open circuit |
| 2 (352A) and 1 (C352B) | at rest | Open circuit | |
| 2 (352A) and 2 (C352B) | at rest | Open circuit | |
| 2 (352A) and 1 (C352C) | at rest | Open circuit | |
| 2 (352A) and 2 (C352C) | at rest | Open circuit | |
| 2 (352A) and 1 (C352D) | at rest | Open circuit | |
| 2 (352A) and 2 (C352D) | at rest | Open circuit | |
| Ground Checks before any other tests | 1 (352A) and 2 (C352A) | at rest | Open circuit |
| 1 (352A) and 1 (C352B) | at rest | Closed circuit | |
| 1 (352A) and 2 (C352B) | at rest | Closed circuit | |
| 1 (352A) and 1 (C352C) | at rest | Closed circuit | |
| 1 (352A) and 2 (C352C) | at rest | Closed circuit | |
| 1 (352A) and 1 (C352D) | at rest | Closed circuit | |
| 1 (352A) and 2 (C352D) | at rest | Closed circuit | |
| Front Height circuit | 2 (C352A) and 1 (C352B) | Up | Closed circuit |
| 2 (C352A) and 2 (C352B) | Down | Closed circuit | |
| Backrest circuit | 2 (C352A) and 1 (C352C) | Froward | Closed circuit |
| 2 (C352A) and 2 (C352C) | Back | Closed circuit | |
| Horizontal circuit | 2 (C352A) and 1 (C352D) | Forward | Closed circuit |
| 2 (C352A) and 2 (C352D) | Back | Closed circuit |