Component testing procedure
COMPONENT TESTING PROCEDURE CHART
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Left mirror | Selector switch left | ||
| Up | 6 and 1 5 and 3 |
Up | Closed circuit |
| Down | 3 and 6 5 and 1 |
Down | Closed circuit |
| Left | 1 and 8 3 and 6 |
Left | Closed circuit |
| Right | 6 and 1 3 and 8 |
Right | Closed circuit |
| Right mirror | Selector switch right | ||
| Up | 2 and 3 6 and 1 |
Up | Closed circuit |
| Down | 3 and 6 2 and 1 |
Down | Closed circuit |
| Left | 6 and 3 7 and 1 |
Left | Closed circuit |
| Right | 3 and 7 6 and 1 |
Right | Closed circuit |