Component testing procedure
COMPONENT TESTING PROCEDURE CHART
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Horizontal circuit | 12, C3387A and 2, C3387A 7, C3387A and 4, C3387A |
Forward | Closed circuit |
| Closed circuit | |||
| 12, C3387A and 4, C3387A 7, C3387A and 2, C3387A |
Rearward | Closed circuit | |
| Closed circuit | |||
| Front Height circuit | 12, C3387A and 11, C3387A 7, C3387A and 10, C3387A |
Up | Closed circuit |
| Closed circuit | |||
| 12, C3387A and 10, C3387A 7, C3387A and 11, C3387A |
Down | Closed circuit | |
| Closed circuit | |||
| Rear Height circuit | 12, C3387A and 3, C3387A 7, C3387A and 5, C3387A |
Up | Closed circuit |
| Closed circuit | |||
| 12, C3387A and 5, C3387A 7, C3387A and 3, C3387A |
Down | Closed circuit | |
| Closed circuit | |||
| Recline circuit | 12, C3387A and C3387A 7, C3387A and 8, C3387A |
Incline | Closed circuit |
| Closed circuit | |||
| 12, C3387A and 8, C3387A 7, C3387A and 9, C3387A |
Recline | Closed circuit | |
| Closed circuit |