Quick Release Coupling
Disconnect
NOTE:
When reusing liquid tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE:
Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE:
Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE:
Type 1
- Refer to: Gasoline and Gasoline-Ethanol Fuel Systems Health and Safety Precautions ( GASOLINE AND GASOLINE-ETHANOL FUEL SYSTEMS HEALTH AND SAFETY PRECAUTIONS ).
- If servicing a liquid fuel tube quick release coupling, release the fuel system pressure.
Refer to: Fuel System Pressure Release ( Fuel System Pressure Release ).
- Disconnect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
- Separate the tabs of the retainer clip and pull it to the outward position in the quick release coupling
- Depress the retainer clip and disconnect the quick release coupling from the tube.
WARNING:
Before beginning any service procedure in this service information, refer to Safety Warnings in
SERVICE INFORMATION
General Information. Failure to follow this instruction may result in serious personal injury.
NOTE:
When reusing liquid or vapor tube quick release couplings, make sure to use compressed air to remove any foreign material from the retaining clip area before disconnecting from the tube.
Connect
- Inspect and clean both quick coupling ends.
- Install the quick release coupling onto the tube.
- Press the retainer clip into the quick release coupling body until flush and the tabs are locked in place.
- Connect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
NOTE:
Inspect and clean both quick release coupling ends.
NOTE:
Make sure the retainer clip is fully seated and locked onto the tube by pulling on the quick release coupling.
Disconnect
NOTE:
When reusing liquid tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE:
Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE:
Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE:
Type 2
- Refer to: Gasoline and Gasoline-Ethanol Fuel Systems Health and Safety Precautions ( GASOLINE AND GASOLINE-ETHANOL FUEL SYSTEMS HEALTH AND SAFETY PRECAUTIONS ).
- If servicing a liquid fuel tube quick release coupling, release the fuel system pressure.
Refer to: Fuel System Pressure Release ( Fuel System Pressure Release ).
- Disconnect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
- Release the lock tab on the quick release coupling.
- Separate the quick release coupling from the fitting.
WARNING:
Before beginning any service procedure in this service information, refer to Safety Warnings in
SERVICE INFORMATION
General Information. Failure to follow this instruction may result in serious personal injury.
NOTE:
When reusing liquid or vapor tube quick release couplings, make sure to use compressed air to remove any foreign material from the retaining clip area before disconnecting from the tube.
Connect
- Release the lock tab and install the quick release coupling onto the fitting.
- Apply the lock tab into the latched position.
- Pull on the quick release coupling to make sure it is securely fastened.
- Connect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
NOTE:
Inspect and clean both quick release coupling ends.
Disconnect
NOTE:
When reusing liquid tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE:
Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE:
Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE:
Type 3
- Refer to: Gasoline and Gasoline-Ethanol Fuel Systems Health and Safety Precautions ( GASOLINE AND GASOLINE-ETHANOL FUEL SYSTEMS HEALTH AND SAFETY PRECAUTIONS ).
- If servicing a liquid fuel tube quick release coupling, release the fuel system pressure.
Refer to: Fuel System Pressure Release ( Fuel System Pressure Release ).
- Disconnect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
- Disconnect the fuel tube quick release coupling.
- Separate the quick release coupling from the fitting.
WARNING:
Before beginning any service procedure in this service information, refer to Safety Warnings in
SERVICE INFORMATION
General Information. Failure to follow this instruction may result in serious personal injury.
NOTE:
When reusing liquid or vapor tube quick release couplings, make sure to use compressed air to remove any foreign material from the retaining clip area before disconnecting from the tube.
Connect
- Install the quick release coupling onto the tube until it is fully seated.
- Pull on the quick release coupling to make sure it is securely fastened.
- Connect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
NOTE:
Inspect and clean both quick release coupling ends.
Disconnect
NOTE:
When reusing liquid tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip may occur.
NOTE:
Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage may occur. Always install blanking plugs to any open orifices or tubes.
NOTE:
Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
NOTE:
Type 4
- Refer to: Gasoline and Gasoline-Ethanol Fuel Systems Health and Safety Precautions ( GASOLINE AND GASOLINE-ETHANOL FUEL SYSTEMS HEALTH AND SAFETY PRECAUTIONS ).
- If servicing a liquid fuel tube quick release coupling, release the fuel system pressure.
Refer to: Fuel System Pressure Release ( Fuel System Pressure Release ).
- Disconnect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
- Press both retaining tabs inward and remove quick release coupling from fuel tube.
WARNING:
Before beginning any service procedure in this service information, refer to Safety Warnings in
SERVICE INFORMATION
General Information. Failure to follow this instruction may result in serious personal injury.
NOTE:
When reusing liquid or vapor tube quick release couplings, make sure to use compressed air to remove any foreign material from the retaining clip area before disconnecting from the tube.
Connect
- Install the quick release coupling onto the tube until it is fully seated.
- Pull on the quick release coupling to make sure it is securely fastened.
- Connect the battery ground cable.
Refer to: BATTERY DISCONNECT AND CONNECT .
NOTE:
Inspect and clean both quick release coupling ends.