| P0562 |
System Voltage Low |
PCM |
GO to PINPOINT TEST B . |
| P0562 |
System Voltage Low |
Various Modules |
GO to PINPOINT TEST B . |
| P0563 |
System Voltage High |
PCM |
GO to PINPOINT TEST A . |
| P0563 |
System Voltage High |
Various Modules |
GO to PINPOINT TEST A . |
| P0620 |
Generator Control Circuit |
PCM |
GO to PINPOINT TEST C . |
| P0625 |
Generator Field Terminal Circuit Low |
PCM |
GO to PINPOINT TEST D . |
| P0626 |
Generator Field Terminal Circuit High |
PCM |
GO to PINPOINT TEST D . |
| P065B |
Generator Control Circuit Range/Performance |
PCM |
GO to PINPOINT TEST E . |
| All other DTCs |
- |
Various Modules |
REFER to the Master DTC Chart in MULTIFUNCTION ELECTRONIC MODULES
or the
ENGINE CONTROLS - INTRODUCTION (EXCEPT DIESEL & HYBRID) (SECTION 0)
. If directed to this information from another service information, GO to SYMPTOM CHART . |