LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2013 >> Taurus SHO >> Repair and Diagnosis (Single Page) >> Engine Mechanical >> Starter >> Starting System >> Description And Operation >> Starting System >> System Operation >> Network Message Chart
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Network Message Chart

NETWORK INPUT MESSAGES BCM

Broadcast Message Originating Module Message Purpose
RKE data TCM Provides the BCM with the RKE TIC and the button press requesting a remote start.
NETWORK INPUT MESSAGES PCM

Broadcast Message Originating Module Message Purpose
Starter crank request BCM Provides the PCM with ignition switch and hood input status and a request to crank and start the engine during a remote start event.
Remote start request BCM Provides the PCM with a request for remote start.


MODULE NETWORK INPUT MESSAGES RFA

Broadcast Message Originating Module Message Purpose
Remote start command TPM module via LIN Provides the RFA with the IA key command for a remote start.
NETWORK INPUT MESSAGES BCM

Broadcast Message Originating Module Message Purpose
RKE data (with IA) RFA module Provides the BCM with the correct IA key data. Provides a request to the BCM for starting per customer remote start request.
NETWORK INPUT MESSAGES PCM

Broadcast Message Originating Module Message Purpose
Starter crank request BCM Provides the PCM with ignition, hood input status and a request to crank and start the engine during a remote start event.
Remote start request BCM Provides the PCM with a request for remote start.