Module Communications Network DTCS
BCM
| DTC | Description | Action |
|---|---|---|
| U0001:88 | High Speed CAN Communication Bus: Bus Off | A HS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0004:00 | High Speed CAN Communication Bus (+) Low: No Sub Type Information | A HS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0005:00 | High Speed CAN Communication Bus (+) High: No Sub Type Information | A HS-CAN fault is present but the network may still be functional at a degraded level. One or more modules may not communicate and may not be sending or receiving messages. GO to PINPOINT TEST Z |
| U0007:00 | High Speed CAN Communication Bus (-) Low: No Sub Type Information | A HS-CAN fault is present but the network may still be functional at a degraded level. One or more modules may not communicate and may not be sending or receiving messages. GO to PINPOINT TEST Z |
| U0008:00 | High Speed CAN Communication Bus (-) High: No Sub Type Information | A HS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0009:00 | High Speed CAN Communication Bus (-) Shorted to Bus (+): No Sub Type Information | A HS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0010:88 | Medium Speed CAN Communication Bus: Bus Off | A MS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0013:00 | Medium Speed CAN Communication Bus (+) Low: No Sub Type Information | A MS-CAN fault is either currently present or was present at a point in time. The BCM can report this DTC while a fault is present because the BCM communicates with the diagnostic scan tool on the HS-CAN . If no MS-CAN modules communicate, GO to PINPOINT TEST AA If all MS-CAN modules currently communicate, CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0014:00 | Medium Speed CAN Communication Bus (+) High: No Sub Type Information | A MS-CAN fault is present but the network may still be functional at a degraded level. One or more modules may not communicate and may not be sending or receiving messages. GO to PINPOINT TEST AA |
| U0016:00 | Medium Speed CAN Communication Bus (-) Low: No Sub Type Information | A MS-CAN fault is present but the network may still be functional at a degraded level. One or more modules may not communicate and may not be sending or receiving messages. GO to PINPOINT TEST AA |
| U0017:00 | Medium Speed CAN Communication Bus(-) High: No Sub Type Information | A MS-CAN fault is either currently present or was present at a point in time. The BCM can report this DTC while a fault is present because the BCM communicates with the diagnostic scan tool on the HS-CAN . If no MS-CAN modules communicate, GO to PINPOINT TEST AA If all MS-CAN modules currently communicate, CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |
| U0018:00 | Medium Speed CAN Communication Bus (-) Shorted to Bus (+): No Sub Type Information | A MS-CAN fault was present at a point in time. The fault is not currently present since the module is communicating with the diagnostic scan tool. CLEAR the DTC . REPEAT the network test with the diagnostic scan tool. VERIFY the integrity of the connectors and wiring. Refer to MODULE COMMUNICATIONS NETWORK for schematic and connector information. |