Sensors/Inputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FPM B27 40.40 40.39 40.40 40.39 %
FTP B46 2.60/-31 Pa (0) 2.46/-280 Pa (-0.04) 179/-1.45 (-0.21) 1.50/-1.97 (-0.29) VOLTS/kPa (PSI)
AAT B47 12 (53.60) 12 (53.60) 12 (53.60) 10 (50) DEG C (DEG F)
AAT_V B47 3.39 3.39 3.40 3.50 VOLTS
APP2 B60 0.40 0.40 0.63 0.59 VOLTS
APP1 B61 0.79 0.79 1.22 1.15 VOLTS
KEYST B64 ON ON ON ON ON/OFF
BOO2 B66 OFF OFF OFF OFF ON/OFF
BOO1 B67 OFF OFF OFF OFF ON/OFF
O2S12 B72 (I) switching (D) switching (D) switching (D) VOLTS
O2S22 B91 (I) switching (D) switching (D) switching (D) VOLTS
TP2 E9 0.81/16.07 0.50/9.80 0.85/16.47 0.87/17.25 VOLTS/%
TP1 E10 4.18/16.07 4.48/10.19 4.13/16.86 4.12/17.25 VOLTS/%
TP_MAXDIFF E10 -0.06 0 -0.12 -0.06 %
IAT E27 2.15/31 (87.80) 2.25/29 (84.20) 2.18/30 (86) 2.24/29 (84.20) VOLTS/DEG C (DEG F)
MAP E32 98 (14.21) 34 (4.93) 39 (5.66) 44 (6.38) kPa (PSI)
MAP_GAUGE E32 3 (0) 67 (0.01) 62 (0.01) (0.01) Pa (PSI)
MAP_V E32 3.99 1.39 1.55 1.82 VOLTS
O2S11_CUR E35 (I) switching switching switching mA/uA
O2S21_CUR E36 (I) switching switching switching mA/uA
IMRC2M E44 1.18 4.03 4.03 1.18 VOLTS
IMRC1M E45 3.89 1.06 1.06 3.89 VOLTS
CHT E47 3.45/95 (203) 3.41/94 (201.20) 3.28/94 (201.20) 3.23/94 (201.20) VOLTS/DEG C (DEG F)
KNOCK_1 E53 0 144 275 269 COUNT
KNOCK_2 E68 0 187 173 178 COUNT
HTRCM12 E78 0 0 0 0 mA
HTRCM22 E83 0 0 0 0 mA
AC_REQ PID NO NO NO NO YES/NO
APP PID 0 0 15 11 %
APP_MAXDIFF PID 0 0 -0.06° -0.06° DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
APP1 (APP_D) PID 15.68 15.68 25.09 22.74 %
APP2 (APP_E) PID 7.84 7.84 12.54 11.76 %
B+ PID 13.21 14.80 14.57 14.57 VOLTS
BARO PID 98 (14.21) 155.19 98 (14.21) 155.19 98 (14.21) 155.19 99 (14.36) 156.11 kPa (PSI)/Hz
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
BRKOVRD_POSS PID 198 198 199 199 NUMERIC VALUE
CLRDIST PID 0.99 (0.62) 0.99 (0.62) 2 (1.24) 2.99 (1.86) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 19864.15 (12343.01) 19864.15 (12343.01) 19864.15 (12343.01) 19866.14 (12344.25) KM (MILES)
DTCCNT PID 0 0 0 0 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 14.55:1 14.93:1 15.12:1 RATIO
EQ_RAT21 PID 0:1 14.50:1 14.90:1 14.95:1 RATIO
ETC_ACT PID 8.28 1.22 5.41 5.87 DEG
ETC_TRIM PID -0.41 -0.41 -0.59 -0.59 DEG
FF_INF PID 9.80 9.80 9.80 9.80 %
FF_LRND PID YES YES YES YES YES/NO
FLI PID 78.82 (H) 79.21 (H) 74.51 (H) 76.86 (H) %
INJPWR_M PID 12.90 14.49 14.56 14.40 VOLTS
LOAD PID 0.00 (I) 28.23 35.29 41.17 %
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 0 1 COUNT
O2S11_IMPED PID 5 0.09 0.09 0.09 VOLTS
O2S11_READY PID NO YES YES YES YES/NO
O2S11_TR PID 0 0 0 0 Kohm
O2S21_IMPED PID 5 0.09 0.09 0.09 VOLTS
O2S21_READY PID NO YES YES YES YES/NO
O2S21_TR PID 0 0 0 0 Kohm
OCTADJ_R_LRND PID 17.70 17.70 17.70 17.70 %
RPM PID 0 595.75 1273.75 1364.25 RPM
SYNC PID NO YES YES YES YES/NO
TP1_LRN_TRIM PID 9 9 9 9 DEG
TP2_LRN_TRIM PID 8.75 8.75 8.75 8.75 DEG
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VCT_EXH_ACT1 PID 0 -0.12 29.25 40.93 DEG
VCT_EXH_ACT2 PID 0 0 29.25 40.62 DEG
VCT_EXH_DIF1 PID 0 0 -0.12 0 DEG
VCT_EXH_DIF2 PID 0 0 -0.12 0.18 DEG
VCT_INT_ACT1 PID 0 20.06 39.87 40 DEG
VCT_INT_ACT2 PID 0 19.81 40.06 39.75 DEG
VCT_INT_DIF1 PID 0 -0.06 0 -0.06 DEG
VCT_INT_DIF2 PID 0 0.12 -0.06 0.18 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Actuators/Outputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
HFC B10 OFF OFF OFF OFF ON/OFF
FP B14 75.99/OFF 29.31/ON 29.22/ON 29.26/ON %/ON/OFF
LFC B17 OFF OFF OFF OFF ON/OFF
EVAPCV B39 0 0 0 100 %/ON-OFF
VCT_EXH_DC1 E4 0 0 51.42 52.26 %
VCT_INT_DC1 E5 0 52.94 57.99 58.17 %
VCT_EXH_DC2 E6 0 0 50.36 51.79 %
VCT_INT_DC2 E7 0 52.59 59.10 58.97 %
IMRC E59/E60 ON OFF OFF OFF ON/OFF
EVAPCP E71 0 24.58 88.27 0 %
HTR12 E78 OFF ON ON ON ON/OFF
HTR11 E79 OFF ON ON ON ON/OFF
O2S11_HTR E79 0 92.15 41.56 30.98 %
HTR22 E83 OFF ON ON ON ON/OFF
HTR21 E84 OFF ON ON ON ON/OFF
O2S21_HTR E84 0 92.15 40.78 36.47 %
AEIS_ACTION PID 0 0 0 0 NUMERIC VALUE
AEIS_POSS PID 0 0 0 0 NUMERIC VALUE
CYL_1-8_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0 0 0 0 KM (MILES)
ETC [TAC_PCT] PID 9.02 1.17 6.27 6.66 %
EVAP020C PID NO NO NO NO YES/NO
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
INJ1-8_OFF PID -- -- -- -- --/DISABLE
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MIL PID OFF OFF OFF OFF ON/OFF
O2_DS_DISBL PID YES NO NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
RO2FT1 PID 0 -0.75 -1.47 1.51 %
RO2FT2 PID 0 -0.75 -1.47 -1.47 %
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 44.25 11.75 38 36.25 DEG
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
Other PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VREF B52/B66/E34 5 5 5 5 VOLTS
VPWR B97/B99 VBAT VBAT VBAT VBAT VOLTS