Normal Operation and Fault Conditions
The ABS module monitors various inputs and compares the values to what should be expected. If the values received are out of range or not what should be expected, the ABS module sets a DTC.
PPT Y ABS MODULE DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| C0001:01 | TCS Control Channel "A" Valve 1: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0002:01 | TCS Control Channel "A" Valve 2: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0003:01 | TCS Control Channel "B" Valve 1: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0004:01 | TCS Control Channel "B" Valve 2: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0010:01 | Left Front Inlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0011:01 | Left Front Outlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0014:01 | Right Front Inlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0015:01 | Right Front Outlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0018:01 | Left Rear Inlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C0019:01 | Left Rear Outlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C001C:01 | Right Rear Inlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| C001D:01 | Right Rear Outlet Control: General Electrical Failure | Sets when the ABS module detects an internal fault. |
| U3000:49 | Control Module: Internal Electronic Failure | Sets when the ABS module detects an internal fault. |
Possible Causes
- Incorrect sensor input
- Stuck valve
- ABS module
Harness Side
- Y1: RECHECK THE ABS MODULE FOR THE DTC
- Ignition ON, engine OFF.
- Clear the ABS DTCs.
- Ignition OFF.NOTE: If DTC U2007:4B or U3000:4B is present, allow the vehicle to cool for 30 minutes.
- Ignition ON, engine OFF.
- Carry out the ABS self-test.
- Is the concern still present?
Yes No Go to Y2. The concern is not present at this time. The fault may have been caused by a temporary concern. If this is a constant intermittent concern, Go to Y2.
- Y2: CHECK FOR CORRECT ABS MODULE OPERATION
- Ignition OFF.NOTE: The battery must be removed to access the ABS module electrical connector.
- Remove the battery. REFER to Charging System (Battery, Battery Mounting And Battery Cables) .
- ABS Module connector disconnected. (C135)
- Using a good light source, inspect all disconnected electrical connectors for the following:
- corrosion - install new connector or terminal and clean the module pins
- damaged or bent pins - install new terminals or pins
- pushed-out pins - install new pins as necessary
- spread terminals - install new terminals as necessary
- Install the battery. REFER to Charging System (Battery, Battery Mounting And Battery Cables) .
- Operate the system and determine if the concern is still present.
- Is the concern still present?
Yes No INSTALL a new ABS module.
CHECK OASIS for any applicable Technical Service Bulletins TSBs.
If a TSB exists for this concern, DISCONTINUE this test and FOLLOW the TSB instructions.
If no TSBs address this concern, INSTALL a new ABS module.
REFER to Anti-Lock Brake System (ABS) And Stability Control .
ORDER a replacement ABS module and INCLUDE the RVC on the form.
If this is a Ford paid repair, INCLUDE the RVC on the warranty claim form.
When complete, SELECT the "X" in the top right corner to CLOSE this procedure.The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.
If this is a Ford paid repair, INCLUDE the RVC on the warranty claim form.
When complete, SELECT the "X" in the top right corner to CLOSE this procedure.
- Ignition OFF.