Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT PID 23 (73.4) 13 (55.4) 14 (57.2) 14 (57.2) DEG C (DEG F)
APP1 APP Sensor 0 0 0 0 %
APP2 APP Sensor 8.06 8.23 8.23 8.23 %
APP2 APP Sensor 1.96 1.96 1.96 1.96 VOLTS
B+ PID 12.7 13-14 13-14 13-14 VOLTS
BARO PID 14.35/156.11/99.00 14.35/156.11/99.00 14.35/156.11/99.00 14.35/156.11/99.00 PSI/Hz/kPa
BPP BPP Switch OFF ON (C) OFF OFF ON/OFF
ECT ECT Sensor 3.27/105 (221) 3.51/97 (206.6) 3.9/84 (183.2) 3.78/88 (190.4) VOLTS/DEG C (DEG F)
FLI Fuel Level Sensor 70.19 57.25 66.66 67.84 %
HTRCM11 HO2S11 Sensor 1.65 1.65 1.65 1.48 AMPS
HTRCM12 HO2S12 Sensor 615 615 615 622 mA
IAT IAT Sensor 1.27/62 (143.6) 1.79/49 (120.2) 3.42/16 (60.8) 4.04/2 (35.6) VOLTS/DEG C (DEG F)
LOAD PID 0 (D) 27.45 29.41 44.31 %
MAP MAP Sensor 4.02/98.93/14.35/29.2 1.25/30.95/4.49/9.2 2.52/61.98/8.99/17.8 2.32/51.98/7.54/15.4 VOLTS/kPa/PSI/inHg
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID NO NO NO NO YES/NO
O2S11 HO2S11 Sensor (D) switching (A) switching (A) switching (A) VOLTS
O2S12 HO2S12 Sensor (D) (B) (B) (B) VOLTS
RPM CKP Sensor 0 698.3 1918 1807 RPM
SYNC PID NO YES YES YES YES/NO
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVAPCP EVAPCP Valve OFF OFF ON ON ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HFC PID OFF ON OFF OFF ON/OFF
IMTV IMTV Solenoid OFF ON ON ON ON/OFF
IMRC IMRC Solenoid OFF ON ON ON ON/OFF
FP Fuel Pump Control Module OFF ON ON ON ON/OFF
FUELPW_CYL1-4 PID 10.74 2.96 2.23 2.23 MILLISECOND
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
LFC PID OFF ON OFF OFF ON/OFF
LONGFT1 PID (D) -20 TO +20 -20 TO +20 -20 TO +20 %
SHRTFT1 PID (D) -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 10 10.25 39 27.25 DEG
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID 12.52 13-14 13-14 13-14 VOLTS
VREF PID 5 5 5 5 VOLTS