DTC Description Action
B1162 Power Running Board Hall Effect Sensor Power Circuit Short to Battery GO to Pinpoint Test E .
B1163 Left Power Running Board Hall Effect Sensor Failure GO to Pinpoint Test E .
B1164 Power Running Board Hall Effect Sensor Power Circuit Short To Ground GO to Pinpoint Test E .
B1167 Left Power Running Board Deploy and/or Stow Circuit Short To Battery GO to Pinpoint Test D .
B1168 Left Power Running Board Stow Circuit Short To Ground GO to Pinpoint Test D .
B1169 LH Motor Traveled Too Far LH motor is freewheeling (broken geartrain linkage). INSTALL a new LH Power Running Board (PRB) motor. REFER to Power Running Board (PRB) Motor .
B116A RH Motor Traveled Too Far RH motor is freewheeling (broken geartrain linkage). INSTALL a new RH PRB motor. REFER to Power Running Board (PRB) Motor .
B116B LH Power Running Board Motor Short GO to Pinpoint Test D .
B116C RH Power Running Board Motor Short GO to Pinpoint Test D .
B116D LH Power Running Board Motor Line Open GO to Pinpoint Test D .
B116E RH Power Running Board Motor Line Open GO to Pinpoint Test D .
B1170 Right Power Running Board Hall Effect Sensor Failure GO to Pinpoint Test E .
B1171 Left Power Running Board Hall Effect Signal Noisy INSTALL a new LH PRB motor. REFER to Power Running Board (PRB) Motor .
B1172 Right Power Running Board Hall Effect Signal Noisy INSTALL a new RH PRB motor. REFER to Power Running Board (PRB) Motor .
B1175 Right Power Running Board Stow Circuit Short To Ground GO to Pinpoint Test D .
B1178 Right Power Running Board Deploy and/or Stow Circuit Short To Battery GO to Pinpoint Test D .
B1317 Battery Voltage High GO to Pinpoint Test F .
B1318 Battery Voltage Low GO to Pinpoint Test F .
B1342 ECU is Faulted INSTALL a new PRB module. REFER to Power Running Board (PRB) Module .
B2139 Data Mismatch (receive data does not match what was expected) REFER to Multifunction Electronic Modules .
B2813 LH Power Running Board Stow Time Fail GO to Pinpoint Test B .
B2814 LH Power Running Board Deploy Time Fail GO to Pinpoint Test B .
B2816 RH Power Running Board Stow Time Fail GO to Pinpoint Test C .
B2817 RH Power Running Board Deploy Time Fail GO to Pinpoint Test C .
U1900 CAN Communication Bus Fault - Receive Error Do not install a new PRB module as part of the repair for a PRB DTC U1900 fault. The PRB is not the source of the fault when DTC U1900 is present. REFER to Module Communications Network to diagnose the Controller Area Network (CAN) concern.
U2050 No Application Present INSTALL a new PRB module. REFER to Multifunction Electronic Modules . REPEAT the self-test.
All other DTCs - REFER to the Master DTC Chart in Multifunction Electronic Modules .