Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 31 (87.8) 28 (82.4) 31 (87.8) 24 (75.2) DEG C (DEG F)
AAT_V AAT Sensor 2.38 2.57 2.37 2.73 VOLTS
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 8.50 14.00 %
APP_MAXDIFF PID 0 0 0.06 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
APP1 APP Sensor 0.75 0.75 1.00 1.04 VOLTS
APP1 (APP_D) APP Sensor 14.90 14.90 20 20.78 %
APP2 APP Sensor 0.38 0.38 0.49 0.52 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 9.80 10.19 %
B+ PID 12.59 14.42 14.47 14.44 VOLTS
BARO PID 94 (13.63)/ 94 (13.63)/151.53 94 (13.63)/151.53 93 (13.49)/150.62 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
BRKOVRD_POSS PID 127 127 128 128 NUMERIC VALUE
CHT CHT Sensor 3.52/95 (203) 3.33/97 (206.6) 3.35/94 (201.2) 3.35/93 (199.4) VOLTS/DEG C (DEG F)
CPP_BOT CPP Switch NO NO NO NO YES/NO
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 2215.62 (1376.72) 2215.62 (1376.72) 2215.62 (1376.72) 2217.12 (1377.65) KM (MILES)
ECT1 ECT Sensor 95 (203) 96 (204.8) 95 (203) 93 (199.4) DEG C (DEG F)
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0/0:1 0.98/14.35:1 1.01/14.72:1 1/14.59:1 RATIO
EQ_RAT21 PID 0/0:1 0.98/14.38:1 1.03/15.11:1 0.99/14.45:1 RATIO
ETC_ACT PID 7.97 0.75 5.60 5.94 DEG
ETC_TRIM PID -0.33 -0.33 -0.45 -0.34 DEG
FLI Fuel Level Sensor 30.19 (H) 29.02 (H) 27.05 (H) 28.23 (H) %
FPM Fuel Pump Control Module 40.40 40.40 40.98 40.40 %
FTP FTP Sensor 2.63/21Pa (0) 2.34/-486Pa (-0.07) 1.94/-1.18 (-0.17) 2.61/-5 (-0.73) VOLTS/kPa (PSI)
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM22 HO2S22 Sensor 0 0 0 0 mA
IAT IAT Sensor 1.73/41 (105.8) 1.94/36 (96.8) 2.11/32 (89.6) 2.19/30 (86) VOLTS/DEG C (DEG F)
IMRC1M IMRC1M Sensor 3.88 1.11 1.11 1.11 VOLTS
IMRC2M IMRC2M Sensor 1.25 4.04 4.05 4.05 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS1 Sensor 0 133 322 222 COUNT
KNOCK_2 KS2 Sensor 0 87 285 239 COUNT
LOAD PID 0.00 (I) 26.27 34.11 44.31 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0 5.27 9.69 8.96 g/s
MAF_HZ MAF Sensor 669.25 (Hz) 1.95 2.58 2.52 kHz
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 51 40 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 0.09 0.09 0.09 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.09 0.09 0.09 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OCTADJ_R_LRND PID -9.55 -9.55 -9.55 -9.55 %
RO2FT1 PID 0 0 -1.47 1.51 %
RO2FT2 PID 0 0 -1.89 3.01 %
RPM CKP Sensor 0 664 1299.75 1464.75 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.16/16.47 4.49/10.58 4.37/12.15 4.33/12.94 VOLTS/%
TP1_LRN_TRIM ETBTPS 9 9 9 9 DEG
TP2 ETBTPS 0.82/16.47 0.49/9.80 0.61/12.15 0.65/12.94 VOLTS/%
TP2_LRN_TRIM ETBTPS 8.87 8.87 8.87 8.87 DEG
VCT_EXH_ACT1 PID 0 -0.25 0.43 39.87 DEG
VCT_EXH_ACT2 PID 0 0 0.25 39.75 DEG
VCT_EXH_DIF1 PID 0 0 -0.43 -0.75 DEG
VCT_EXH_DIF2 PID 0 0 -0.18 -1.68 DEG
VCT_INT_ACT1 PID 0 20.50 30 39.93 DEG
VCT_INT_ACT2 PID 0 19.93 29.87 39.93 DEG
VCT_INT_DIF1 PID 0 -0.5 0 0 DEG
VCT_INT_DIF2 PID 0 0 0.06 0 DEG
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS_ACTION PID 0 0 0 0 NUMERIC VALUE
AEIS_POSS PID 0 0 0 0 NUMERIC VALUE
CYL_1-8_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0 0 0 0 KM (MILES)
ETC [TAC_PCT] PID 9.02 0.78 6.27 6.66 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 15.04 82.46 81.75 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 29.3/ON 29.52/ON 29.46/ON %/ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
IMRC IMRC Solenoid ON OFF OFF OFF ON/OFF
INJ1-8_OFF Injector 1-8 - - - - -/DISABLE
LFC PID OFF OFF OFF OFF ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 60.78 49.02 37.64 38.43 %
O2S21_HTR HO2S21 Sensor 55.78 50.19 45.49 39.21 %
O2_DS_DISBL PID YES NO NO NO YES/NO
SPARKADV PID 16.50 4.00 41.75 47.25 DEG
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL TORQUE BASED DECEL NONE REQUESTED STATUS
VCT_EXH_DC1 VCT12 Solenoid 0 0 0 51.96 %
VCT_INT_DC1 VCT11 Solenoid 0 54.90 57.50 57.52 %
VCT_EXH_DC2 VCT22 Solenoid 0 0 0 52.08 %
VCT_INT_DC2 VCT21 Solenoid 0 58.10 60.89 60.01 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS