| 2.0L EcoBoost without climate controlled seats - 175 amp |
| Generator pulley ratio |
2.47 |
| Rating |
119.5 amps at 750 rpm (min) to 180 amps at 2, 500 rpm (max) |
| Voltage regulator type |
Electronic internal with generator |
| 2.0L EcoBoost with climate controlled seats - 200 amp |
| Generator pulley ratio |
2.47 |
| Rating |
134 amps at 750 rpm (min) to 208 amps at 2, 500 rpm (max) |
| Voltage regulator type |
Electronic internal with generator |
| 2.7L EcoBoost without climate controlled seats - 175 amp |
| Generator pulley ratio |
2.47 |
| Rating |
103.4 amps at 750 rpm (min) to 175.1 amps at 2, 500 rpm (max) |
| Voltage regulator type |
Electronic internal with generator |
| 2.7L EcoBoost with climate controlled seats - 200 amp |
| Generator pulley ratio |
2.47 |
| Rating |
123.9 amps at 750 rpm (min) to 219 amps at 2, 500 rpm (max) |
| Voltage regulator type |
Electronic internal with generator |
| 3.5L Duratec without climate controlled seats - 175 amp |
| Generator pulley ratio |
2.47 |
| Rating |
119.5 amps at 750 rpm (min) to 180 amps at 2, 500 rpm (max) |
| Voltage regulator type |
Electronic internal with generator |
| 3.5L Duratec with climate controlled seats - 200 amp |
| Generator pulley ratio |
2.47 |
| Rating |
134 amps at 750 rpm (min) to 208 amps at 2, 500 rpm (max) |
| Voltage regulator type |