Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 7 (44.60) 6 (42.80) 3 (37.40) 3 (37.40) DEG C (DEG F)
AAT_V AAT Sensor 3.64 3.69 3.83 3.82 VOLTS
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 7 16.50 %
APP_MAXDIFF PID 0 0 0 -0.06 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
APP1 APP Sensor 0.77 0.77 0.98 1.30 VOLTS
APP1 (APP_D) APP Sensor 15.29 15.29 20 25.88 %
APP2 APP Sensor 0.38 0.38 0.49 0.65 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 9.80 12.94 %
B+ PID 12.92 14.32 14.52 14.42 VOLTS
BARO PID 99.97 (14.50)/157.02/401.46 99.97 (14.50)/157.02/401.46 99.97 (14.50)/157.02/401.46 99.97 (14.50)/157.02/401.46 kPa (PSI)/Hz/in-H 2 O
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
BRKOVRD_POSS PID 3 3 4 4 NUMERIC VALUE
CHT CHT Sensor 0.65/87 (188.60) 0.69/84 (183.20) 3.77/88 (190.40) 3.71/90 (194) VOLTS/DEG C (DEG F)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 10.49 (6.52) 10.49 (6.52) 14.98 (9.31) 13.49 (8.38) KM (MILES)
EQ_RAT11 PID 0/0:1 1/14.70:1 1.03/15.14:1 1.01/14.82:1 RATIO
ETC_ACT PID 7.99 2.54 7.03 9.45 DEG
ETC_TRIM PID -0.02 (E) -0.02 (E) -0.02 (E) -0.02 (E) DEG
FLI Fuel Level Sensor 81.56 (C) 81.56 (C) 74.51 (C) 77.64 (C) %
FPM PID 40.79 40.32 40.32 40.32 %
FTP FTP Sensor 0/-4.55 (-0.66) 0/-4.55 (-0.66) 0/-4.55 (-0.66) 0/-4.55 (-0.66) VOLTS/kPa (PSI)
HTRCM11 HO2S11 Sensor 0 2.53 2.61 2.61 AMPS
HTRCM12 HO2S12 Sensor 0 702 705 705 mA
IAT IAT Sensor 3.60/13 (55.40) 3.72/10 (50) 3.88/6 (42.80) 3.92/5 (41) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.91 14.42 14.47 14.47 VOLTS
KNOCK_1 KS1 Sensor 258 269 334 359 N/A
LOAD PID 0 (D) 25.09 30.58 58.43 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0 3.17 7.32 15.60 g/s
MAF_HZ MAF Sensor 0.66 2.37 3.24 4.38 kHz
MAP MAP Sensor 4.05/99.97 (14.50) 1.30/31.99 (4.64) 1.14/33.99 (4.93) 2.52/61.98 (8.99) VOLTS/kPa (PSI)
MAP_GAUGE MAP Sensor 4.01 277.01 268.98 156.57 in-H 2 O
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 0 0 COUNT
O2S11_CUR HO2S11 Sensor (D) switching (A) switching (A) switching (A) uA
O2S11_IMPED HO2S11 Sensor 5 0.09 0.09 0.09 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 61.20 61.20 60.60 60.60 Kohm
O2S12 HO2S12 Sensor 0.06 (B) 0.82 (B) 0.48 (B) 0.65 (B) VOLTS
RO2FT1 PID 0 -0.47 2.06 -0.70 %
RPM CKP Sensor 0 772 1914.50 1798.50 RPM
SHRTFT1 PID (D) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.09/18.03 4.34/12.94 4.14/16.86 3.90/21.56 VOLTS/%
TP2 ETBTPS 1.23/24.70 0.74/14.90 1.03/22.35 1.60/31.76 VOLTS/%
TPMODE PID CT CT PT PT CLOSED/PART/WIDE OPEN THROTTLE
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VSS PID 0 0 48 KM/H (30 MPH) 89 KM/H (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EGR_STEP EGR Valve 0     0 12 31 POSITION  
EGRMC1F EGR Actuator NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC2F EGR Actuator NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC3F EGR Actuator NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC4F EGR Actuator NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRPCT PID 0 0 22.74 59.60 %
ETC [TAC_PCT] PID 9.41 2.74 8.23 11.37 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 10.73 12.80 77.58 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID NO NO NO NO YES/NO
FP Fuel Pump Control Module OFF ON ON ON ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20 31.37 24.70 25.09 %
O2_DS_DISBL PID YES NO NO NO YES/NO
SPARKADV PID 29.50 12.75 45.50 38 DEG
TQ_CNTRL PID ANTI-THEFT IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
VCTADV PID 0 -0.37 -0.18 0 DEG
VCTADVERR PID 0 0.37 0.18 0.12 DEG
VCTDC VCT1 Solenoid 0 0 0 0 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS