LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2018 >> Transit Connect Titanium >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Reference Values (Except Diesel & Hybrid) >> 6.8L E-Series >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 16 13.50 %
APP1 APP Sensor 0.78 0.78 1.30 1.22 VOLTS
APP1 (APP_D) APP Sensor 15.29 15.29 25.88 24.31 %
APP2 APP Sensor 0.39 0.39 0.65 0.61 VOLTS
APP2 (APP_E) APP Sensor 7.84 7.84 12.94 12.15 %
APP_MAXDIFF PID 0 0 0 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
B+ PID 12.82 14.44 14.34 14.24 VOLTS
BARO PID 98 (14.21)/155.19 98 (14.21)/155.19 98 (14.21)/155.19 99 (14.36)/156.11 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 2 2 3 3 NUMERIC VALUE
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
CHT CHT Sensor 3.68/91 (195.80) 3.72/90 (194) 3.62/93 (199.40) 3.63/93 (199.40) VOLTS/DEG C (DEG F)
CLRDIST PID 3.99 (2.48) 3.99 (2.48) 3.99 (2.48) 5.99 (3.72) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 3.99 (2.48) 3.99 (2.48) 3.99 (2.48) 5.49 (3.41) KM (MILES)
DTCCNT PID 0 0 0 0 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 14.68:1 14.61:1 14.61:1 RATIO
EQ_RAT21 PID 0:1 14.66:1 14.60:1 14.66:1 RATIO
ETC_ACT PID 8.02 2.32 4.90 9.19 DEG
ETC_TRIM PID 0.45 0.46 0.47 0.47 DEG
FLI Fuel Level Sensor 70.58 (H) 69.02 (H) 32.88 (H) 65.09 (H) %
FPM PID 60.60 60 60.99 60.60 %
FTP FTP Sensor 2.54/-143Pa (-0.02) 2.50/-203Pa (-0.03) 1.67/-1.67 (-0.24) 1.54/-1.89 (-0.27) VOLTS/kPa (PSI)
HTRCM11 HO2S11 Sensor 0 0 0 0 mA
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM21 HO2S21 Sensor 0 0 0 0 mA
IAT IAT Sensor 2.95/14 (57.20) 3.04/12 (53.60) 3.38/6 (42.80) 3.51/3 (37.40) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.90 14.39 14.19 14, 24 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
LOAD PID 0.00 (I) 19.60 41.17 19.60 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0.02 7.14 28.25 16.74 g/s
MAF_HZ MAF Sensor 702.50 Hz 2.14 3.93 3.20 kHz
MIL_DIS PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 2 11 13 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 0.09 0.09 0.09 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.09 0.09 0.09 VOLTS
O2S21_READY HO2S21 Sensor NO NO YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
PTO PID OFF OFF OFF OFF ON/OFF
PTOIR_V PID 0 0 0 0 VOLTS
PTOLOAD PID OFF OFF OFF OFF OFF/ON
RO2FT1 PID 0 0 -0.50 1.58 %
RO2FT2 PID 0 0 -0.50 1.58 %
RPM CKP Sensor 0 769 1280 1918.50 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.07/18.43 4.31/13.72 4.22/15.68 4.22/15.29 VOLTS/%
TP2 ETBTPS 1.25/24.70 0.77/15.29 0.95/20 0.95/18.82 VOLTS/%
TP_MAXDIFF PID 0 0 0 0 %
VSS PID 0 0 48 KM/H (30 MPH) 89 KM/H (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
CYL 1-10_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
ETC [TAC_PCT] PID 9.41 2.74 5.88 10.98 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 10.09 99.72 98.13 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID YES YES NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 32.46/ON 32.74/ON 32.88/ON %/ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
INJ1-10_OFF Injector 1-10 -- -- -- -- --/DISABLE
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20 30.98 29.80 24.31 %
O2S21_HTR HO2S21 Sensor 20 69.80 31.37 22.74 %
O2_DS_DISBL PID YES YES NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
PTOIL PTO Lamp OFF OFF OFF OFF ON/OFF
SPARKADV PID 5.25 21.75 32.50 32.75 DEG
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS