Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 23 (73.4) 22 (71.6) 19 (66.2) 15 (59) DEG C (DEG F)
AAT_V AAT Sensor 2.80 2.87 3.03 3.22 VOLTS
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 0 20 %
APP1 APP Sensor 0.76 0.76 0.77 1.41 VOLTS
APP1 (APP_D) APP Sensor 15.29 15.29 15.29 30.58 %
APP2 APP Sensor 0.38 0.38 0.38 0.70 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 7.45 13.72 %
APP_MAXDIFF PID 0 0 0 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
B+ PID 12.46 14.39 14.19 14.31 VOLTS
BARO PID 99 (14.36) 156.11 99 (14.36) 156.11 99 (14.36) 156.11 99 (14.36) 156.11 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 34 34 35 35 NUMERIC VALUE
BRKOVR_ACTION PID 2 2 2 2 NUMERIC VALUE
CHT CHT Sensor 3.52/92 (197.6) 3.52/92 (197.6) 3.72/98 (208.4) 3.68/88 (190.4) VOLTS/DEG C (DEG F)
CLRDIST PID 5.99 (3.72) 5.99 (3.72) 11.99 (7.45) 10.99 (6.83) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 14.99 (9.31) 14.99 (9.31) 20.98 (13.04) 19.48 (12.10) KM (MILES)
DTCCNT PID 2 2 2 2 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 14.69:1 14.73:1 14.88:1 RATIO
EQ_RAT21 PID 0:1 14.65:1 14.78:1 14.87:1 RATIO
ETC_ACT PID 8.49 1.62 2.15 3.19 DEG
ETC_TRIM PID 0.20 0.20 0.18 0.18 DEG
FF_INF PID 9.80 9.80 9.80 9.80 %
FF_LRND PID YES YES YES YES YES/NO
FLI Fuel Level Sensor 88.23 (H) 88.62 (H) 91.37 (H) 93.33 (H) %
FPM PID 59.99 60 59.99 59.99 %
FTP FTP Sensor 2.60/-31 (0) 2.47/-254 (-0.04) 2.31/-546 (-0.08) 2.61/-5 (0) VOLTS/Pa (PSI)
FTP_H2O FTP Sensor -0.13 -1.03 -3.34 -0.03 NUMERIC VALUE
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM22 HO2S22 Sensor 0 0 0 0 mA
IAT IAT Sensor 1.82/38 (100.4) 1.86/37 (98.6) 2.02/34 (93.2) 2.16/31 (87.8) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.29 14.14 14.22 14.17 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS1 Sensor 0 95 167 224 COUNT
KNOCK_2 KS2 Sensor 0 102 123 128 COUNT
LOAD PID 0.00 (I) 32.94 39.60 36.47 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAP MAP Sensor 99 (14.36) 37 (5.37) 43 (6.24) 38 (5.51) kPa (PSI)
MAP_GAUGE MAP Sensor (I) 64 (9.28) 58 (8.41) 63 (9.14) kPa (PSI)
MAP_V MAP Sensor 3.96 1.41 1.64 1.47 VOLTS
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 1 1 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 0.99 0.99 0.99 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.99 0.99 0.99 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OSS_SRC OSS Sensor 0 0 1213 2062.75 RPM
RO2FT1 PID 0 0.97 -0.57 0 %
RO2FT2 PID 0 1.12 -0.33 0 %
RPM CKP Sensor 0 600.25 1239 1525 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.06/18.43 4.32/13.33 4.12/17.25 4.29/13.72 VOLTS/%
TP1_LRN_TRIM ETBTPS 15.37 15.37 15.37 15.37 DEG
TP2 ETBTPS 1.29/25.49 0.75/14.90 1.16/23.13 0.81/16.07 VOLTS/%
TP2_LRN_TRIM ETBTPS 7.87 7.87 7.87 7.87 DEG
TP_MAXDIFF PID 0 0 0 0 %
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VCT_EXH_ACT1 PID 0 -0.25 11.93 40.12 DEG
VCT_EXH_ACT2 PID 0 -0.18 12 41 DEG
VCT_EXH_DIF1 PID 0 0.25 -0.68 -1.12 DEG
VCT_EXH_DIF2 PID 0 0.18 0.06 -0.06 DEG
VCT_INT_ACT1 PID 0 0 -9.43 -9.50 DEG
VCT_INT_ACT2 PID 0 -0.37 -9.75 -9.25 DEG
VCT_INT_DIF1 PID 0 0 -0.50 -0.81 DEG
VCT_INT_DIF2 PID 0 0.25 -0.18 -0.93 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS ACTION PID 0 0 0 0 NUMERIC VALUE
AEIS_POSS PID 0 0 0 0 NUMERIC VALUE
CYL 1-6_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0 0 0 0 KM (MILES)
ETC [TAC_PCT] PID 9.41 1.96 2.35 3.52 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 8.82 24.85 82 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPPCT PID 0 9.80 11.37 94.11 %
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 35.30/ON 35.47/ON 35.54/ON %/ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
INJ1-6_OFF Injector 1-6 -- -- -- -- --/DISABLE
LFC PID OFF OFF OFF OFF ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20 30.58 27.05 20 %
O2S21_HTR HO2S21 Sensor 20.39 31.37 26.66 24.70 %
O2_DS_DISBL PID YES NO NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
SPARKADV PID 26 6.75 31.50 27 DEG
VCT_EXH_DC1 VCT12 Solenoid 0 0 39.33 38.76 %
VCT_EXH_DC2 VCT22 Solenoid 0 0 39.59 39.27 %
VCT_INT_DC1 VCT11 Solenoid 0 0 46.49 43.94 %
VCT_INT_DC2 VCT21 Solenoid 0 0 46.89 45.94 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS