Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 21 (69.8) 21 (69.8) 22 (71.6) 22 (71.6) DEG C (DEG F)
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 14 10 %
APP1 APP Sensor 0.76 0.76 1.20 1.09 VOLTS
APP1 (APP_D) APP Sensor 15.29 14.90 23.92 21.56 %
APP2 APP Sensor 0.39 0.38 0.61 0.55 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 12.15 10.98 %
APP_MAXDIFF PID 0 0 0 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
B+ PID 12.64 13.98 13.80 13.77 VOLTS
BARO PID 100 (14.50) 157.02 100 (14.50) 157.02 100 (14.50) 157.02 100 (14.50) 157.02 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 4 4 5 5 NUMERIC VALUE
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
CHT CHT Sensor 3.58/94 (201.2) 3.53/94 (201.2) 3.39/96 (204.8) 3.42/95 (203) VOLTS/DEG C (DEG F)
CLRDIST PID 3.99 (2.48) 3.99 (2.48) 4.99 (3.10) 5.99 (3.72) KM (MILES)
DECHOKE PID NO NO NO NO YES/NO
DIST_BRKOVRD PID 3.49 (2.17) 3.49 (2.17) 3.49 (2.17) 5.49 (3.41) KM (MILES)
DTCCNT PID 2 2 2 2 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 0:1 14.18:1 14.63:1 RATIO
EQ_RAT21 PID 0:1 0:1 14.28:1 14.01:1 RATIO
ETC_ACT PID 7.57 2.15 9.58 9.36 DEG
ETC_TRIM PID 0.39 0.39 0.38 0.38 DEG
FANSS FS Sensor 0 0 0 0 RPM
FLI Fuel Level Sensor 65.09 (H) 65.09 (H) 54.90 (H) 61.56 (H) %
FPM PID 39.99 41 39.98 39.99 %
FTP FTP Sensor 2.65/64 (0.01) 2.65/64 (0.01) 2.28/-589 (-0.09) 2.33/-504 (-0.07) VOLTS/Pa (PSI)
HTRCM11 HO2S11 Sensor 0 0 0 0 mA
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM21 HO2S21 Sensor 0 0 0 0 mA
IAT IAT Sensor 2.23/29 (84.2) 2.33/27 (80.6) 2.47/24 (75.2) 2.54/23 (73.4) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.73 14.05 13.88 13.83 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS1 Sensor 0 105 365 283 COUNT
KNOCK_2 KS2 Sensor 0 165 220 271 COUNT
LOAD PID 0.00 (I) 23.92 36.86 43.52 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 2.31 9.56 33.94 57.09 g/s
MAF_HZ MAF Sensor 743.75 Hz 2.57 4.25 5.18 kHz
MIL_DIS PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 3 3 COUNT
O2BANK1 PID VARIES VARIES VARIES VARIES RICH/LEAN
O2BANK2 PID VARIES VARIES VARIES VARIES RICH/LEAN
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 5 0.09 0.09 VOLTS
O2S11_READY HO2S11 Sensor NO NO YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 5 0.09 0.09 VOLTS
O2S21_READY HO2S21 Sensor NO NO YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
RO2FT1 PID 0 0 -1.23 1.25 %
RO2FT2 PID 0 0 -1.23 1.25 %
RPM CKP Sensor 0 725.75 1509.00 2314.25 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.10/17.64 4.31/13.72 4.05/18.43 3.74/24.70 VOLTS/%
TP1_LRN_TRIM ETBTPS 15.37 15.37 15.37 15.37 DEG
TP2 ETBTPS 1.16/23.13 0.73/14.51 1.22/24.31 1.86/37.25 VOLTS/%
TP2_LRN_TRIM ETBTPS 7.25 7.25 7.25 7.25 DEG
TP_MAXDIFF PID 0 0 0 -0.12 %
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH MPH)
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS ACTION PID 0 0 0 0 NUMERIC VALUE
AEIS_POSS PID 0 0 0 0 NUMERIC VALUE
CYL 1-10_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
ETC [TAC_PCT] PID 9.41 2.35 11.37 11.37 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 0 85.59 63.28 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 31.50/ON 31.73/ON 47.99/ON %/ON/OFF
FUELSYS PID OPEN LOOP OPEN LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HTR11 HO2S11 Sensor OFF OFF ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
IMTV IMTV Solenoid OFF OFF OFF OFF ON/OFF
INJ1-10_OFF Injector 1-10 -- -- -- -- --/DISABLE
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 19.21 0 33.33 26.27 %
O2S21_HTR HO2S21 Sensor 19.21 0 32.15 24.31 %
O2_DS_DISBL PID YES YES NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
SPARKADV PID 29.50 13.75 36.25 18.25 DEG
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS