LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2020 >> Edge ST-Line, FWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Reference Values (Except Diesel & Hybrid) >> 3.5L GTDI Flex >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
APP APP Sensor 0.00 0.00 11.5 6.5 %
APP1 APP Sensor 0.78 0.78 0.98 1.09 VOLTS
APP2 APP Sensor 0.39 0.39 0.50 0.56 VOLTS
B+ PID 12.62 14.22 14.16 14.24 VOLTS
BARO PID 14.35/156.11 14.35/156.11 14.21/155.19 14.35/156.11 PSI/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
CAC_T CACT Sensor 2.43/36 (96.8) 2.39/37 (98.6) 2.74/30 (86.0) 3.37/17 (62.6) VOLTS/DEG C (DEG F)
CHT CHT Sensor 3.43/93 (199.40) 3.41/87 (188.60) 0.65/86 (186.80) 0.60/88 (190.40) VOLTS/DEG C (DEG F)
CLRDIST PID 0 0 0 0 MILES
CRNKCAS_PRS Crankcase Pressure Sensor 0 -68 (-0) -178 (-0.03) -295 (-0.04) Pa (PSI)
CRNKCAS_P_V Crankcase Pressure Sensor 3.95 3.89 3.83 3.81 VOLTS
DECHOKE PID YES NO NO NO YES/NO
EQ_RAT11 PID 0.00 14.61:1 14.60:1 14.55:1 RATIO
EQ_RAT21 PID 0.00 14.60:1 14.59:1 14.47:1 RATIO
ETC_TRIM PID 0.24 (J) 0.25 (J) 0.23 (J) 0.28 (J) DEG
FLI Fuel Level Sensor 49.41 (H) 49.41 (H) 49.41 (H) 49.27 (H) %
FPM Fuel Pump Control Module 60.39 59.99 59.99 60.00 %
FRP FRP Sensor 1.57/7020 (1018.17) 0.74/1570 (227.71) 0.76/1650 (239.31) 0.87/2570 (372.75) VOLTS/kPa
FTP FTP Sensor 2.66/0.01 2.53/-0.02 1.77/-0.21 2.18/-0.11 VOLTS/Pa
FTP_H20 FTP Sensor 0.207 -2.275 -1.379 -0.896 in-H2 O
HTRCM12 HO2S12 Sensor 0 830 923 923 A/mA
HTRCM22 HO2S22 Sensor 0 797 866 891 A/mA
IACKAM2 PID -0.38 -0.44 -0.58 -0.58 NUMERIC VALUE
IAT IAT Sensor 2.37/37 (98.60) 2.29/38 (100.40) 3.21/20 (68.00) 3.88/6 (42.80) VOLTS/DEG C (DEG F)
INJPWR_M PID 0.00 0.00 0.00 0.00 VOLTS
LOAD PID 0.00 (I) 29.02 18.82 26.27 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAP MAP Sensor 14.5/2.42 4.6/0.92 5.8/1.06 8.70/1.53 PSI/VOLTS
MIL_DIS PID 0.00 0.00 0.00 0.00 Miles
MISFIRE PID NO NO NO NO YES/NO
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 4.93 1.01 1.01 1.01 VOLTS
O2S12 HO2S12 Sensor (I) (D) (D) (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 4.93 1.01 1.01 1.01 VOLTS
O2S22 HO2S22 Sensor (I) (D) (D) (D) VOLTS
RPM CKP Sensor 0 676 600 600 RPM
SHRTFT1 PID 0.00 -0.78 0.78 0.78 %
SHRTFT2 PID 0.00 -1.56 2.34 -0.78 %
SYNC PID NO YES YES YES YES/NO
TCBP TCBP Sensor 101.82/14.6 101.82/14.6 100.31/14.55 105.16/15.2 kPa/PSI
TCBP_V TCBP Sensor 1.58 1.59 1.60 1.64 VOLTS
TP1 ETBTPS 4.09 4.29 4.14 4.02 VOLTS
TP2 ETBTPS 1.18 0.79 1.09 1.31 VOLTS
TURBO_BP1_STAT TCBY Valve NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
TURBO_BP2_STAT TCBY2 Valve NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
VCT_INT_ACT1 PID 0.00 0.06 -28.81 -32.56 DEG
VCT_INT_ACT2 PID 0.00 -0.12 -28.87 -32.50 DEG
VCT_INT_DIF1 PID 0.00 0.00 0.43 0.12 DEG
VCT_INT_DIF2 PID 0.00 0.00 0.43 0.00 DEG
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0.00 61.92 33.84 74.1 %
EVAPCV CANV Valve OFF OFF OFF OFF ON/OFF
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING COMPLETE STATUS
FP Fuel Pump Control Module 75.00 25.82 28.56 26.45 %
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
F_VCV Fuel Volume Control Valve 0.00 6.51 17.81 19.76 %-VARYING
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
LFC PID OFF ON ON OFF ON/OFF
O2S11_HTR HO2S11 Sensor 21.56 37.64 35.29 34.11 %
O2S21_HTR HO2S21 Sensor 20.78 38.03 36.86 35.68 %
SPARKADV PID 10 5.25 39.00 38.25 DEG
TURBO_BPASS TCBY Valve OFF OFF OFF OFF ON/OFF
TURBO_BPASS_2 TCBY2 Valve OFF OFF OFF OFF ON/OFF
TURBO_WGATE Turbocharger Wastegate Regulating Valve Solenoid 0.00 0.00 0.00 6.10 %
VCT_INT_DC1 VCT11 Solenoid 0.00 0.00 38.65 44.95 %
VCT_INT_DC2 VCT21 Solenoid 0.00 0.00 44.97 44.88 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID 12 VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS