Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 3 (37.4) 3 (37.4) 4 (39.2) 4 (39.2) DEG C (DEG F)
AAT_V AAT Sensor 3.83 3.83 3.80 3.80 VOLTS
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 7 14 %
APP1 APP Sensor 0.75 0.75 0.99 1.21 VOLTS
APP1 (APP_D) APP Sensor 14.90 14.90 19.60 24.31 %
APP2 APP Sensor 0.38 0.38 0.50 0.62 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 9.80 12.15 %
APP_MAXDIFF PID 0 0 -0.06 -0.12 DEG
B+ PID 12.25 14.68 14.65 14.62 VOLTS
BARO PID 100 (14.50) 157.02 100 (14.50) 157.02 100 (14.50) 157.02 100 (14.50) 157.02 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 5 5 6 6 NUMERIC VALUE
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
CHT CHT Sensor 3.57/92 (197.6) 0.52/88 (190.4) 3.48/92 (197.6) 3.56/89 (192.2) VOLTS/DEG C (DEG F)
CLRDIST PID 0.99 (0.62) 0.99 (0.62) 2 (1.24) 2.99 (1.86) KM (MILES)
CPP_BOT (MT) CPP Switch NO NO NO NO YES/NO
CPP PERCENT (MT) CPP Sensor 0 0 0 0 %
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 32.47 (20.18) 32.47 (20.18) 37.97 (23.59) 36.97 (22.97) KM (MILES)
EQ_RAT11 PID 0:1 14.54:1 14.59:1 14.64:1 RATIO
EQ_RAT21 PID 0:1 14.73:1 14.74:1 14.81:1 RATIO
ETC_ACT PID 7.85 2.18 4.18 6.95 DEG
ETC_TRIM PID 0.49 0.47 0.26 0.30 DEG
FLI Fuel Level Sensor 83.13 (H) 83.13 (H) 75.68 (H) 81.56 (H) %
FLP Fuel Pressure Sensor 397.50 (57.65) 416 (60.34) 399 (57.87) 397.50 (57.65) kPa (PSI)
FLP_V Fuel Pressure Sensor 2.09 2.16 2.10 2.09 VOLTS
FPM PID 39.99 40.40 39.99 40.39 %
FRP FRP Sensor 3.97/24750 (3589.68) 3.83/23780 (3449) 1.34/6030 (874.58) 1.29/5690 (825.26) VOLTS/kPa (PSI)
FRT FRPT Sensor 36 (96.8) 34 (93.2) 43 (109.4) 42 (107.6) DEG C (DEG F)
FRT_V FRT Sensor 1.94 1.99 1.65 1.70 VOLTS
FTP FTP Sensor 2.64/46 (0.01) 2.70/149 (0.02) 2.47/-254 (-0.04) 2.47/-254 (-0.04) VOLTS/kPa (PSI)
FTP_H2O FTP Sensor 0.17 0.55 -1.03 -1.03 NUMERIC VALUE
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM22 HO2S22 Sensor 0 0 0 0 mA
IAT IAT Sensor 2.12/32 (89.6) 2.61/21 (69.8) 3.18/9 (48.2) 3.22/8 (46.4) VOLTS/DEG C (DEG F)
IMRC1M IMRC1M Sensor 3.34 1.43 1.35 1.38 VOLTS
IMRC2M IMRC2M Sensor 3.35 1.47 1.42 1.43 VOLTS
INJPWR_M PID 12.08 14.65 14.65 14.68 VOLTS
INJ_F PID NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS11 Sensor 999 23 83 74 COUNT
KNOCK_2 KS12 Sensor 999 29 54 79 COUNT
KNOCK_3 KS21 Sensor 999 22 60 59 COUNT
KNOCK_4 KS22 Sensor 999 25 52 58 COUNT
LOAD PID 0.00 (I) 20.78 16.86 41.11 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0 4.84 27.76 25.38 g/s
MAF_HZ MAF Sensor 0.70 1.70 3.56 3.44 kHz
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 5 5 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 0.17 0.16 0.17 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.17 0.16 0.17 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
RO2FT1 PID 0 0 1.96 1 %
RO2FT2 PID 0 0 1.99 -0.98 %
RPM CKP Sensor 0 729.25 1206.75 1564.75 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 13.33 7.84 7.84 13.72 %
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED NONE REQUESTED STATUS
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VCT_EXH_ACT1 PID 0 -0.06 46.75 24.37 DEG
VCT_EXH_ACT2 PID 0 -0.12 46.87 24.06 DEG
VCT_EXH_DIF1 PID 0 0.06 0.75 0 DEG
VCT_EXH_DIF2 PID 0 0.06 0.06 0.06 DEG
VCT_INT_ACT1 PID 0 20.06 39.81 40 DEG
VCT_INT_ACT2 PID 0 19.68 40 40.06 DEG
VCT_INT_DIF1 PID 0 -0.06 0.12 0.06 DEG
VCT_INT_DIF2 PID 0 0.25 0 -0.06 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS_ACTION PID 1 1 1 1 NUMERIC VALUE
AEIS_POSS PID 32 32 32 32 NUMERIC VALUE
CYL_1-8_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0.50 (0.31) 0.50 (0.31) 3.49 (2.17) 2.99 (1.86) KM (MILES)
ETC [TAC_PCT] PID 9.02 2.35 4.70 8.23 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 9.23 78.99 78.30 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPPCT PID 0 9.02 78.82 78.03 %
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 17.08/ON 17.06/ON 17.17/ON %/ON/OFF
FRP_DSD PID 320 (46.41) 2750 (398.85) 4120 (597.56) 4740 (687.48) kPa (PSI)
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
F_VCV Fuel Injection Pump 0 0 0 0 %
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
IMRC IMRC Solenoid ON OFF OFF OFF ON/OFF
IMRC_F PID NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
INJ1-8_OFF Injector 1-8 -- -- -- -- --/DISABLE
LFC PID OFF ON ON OFF ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20.39 26.66 23.92 23.92 %
O2S21_HTR HO2S21 Sensor 20.39 28.62 27.45 24.31 %
O2_DS_DISBL PID YES YES NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
RPMDSD PID 800 725 644 644 RPM
SPARKADV PID 33 9.75 37 33 DEG
VCT_EXH_DC1 VCT12 Solenoid 0 0 41.37 0 %
VCT_EXH_DC2 VCT22 Solenoid 0 0 39.73 0 %
VCT_INT_DC1 VCT11 Solenoid 0 51.41 55.47 55.45 %
VCT_INT_DC2 VCT21 Solenoid 0 56.11 58.71 58.37 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS