Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 17 (62.6) 17 (62.6) 19 (66.2) 17 (62.6) DEG C (DEG
AAT_ V AAT Sensor 3.13 3.13 3.03 3.12 VOLTS
AC_ REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 12.50 0 %
APP1 APP Sensor 0.78 0.78 1.19 0.85 VOLTS
APP1 (APP_D) APP Sensor 15.68 15.68 23.92 16.47 %
APP2 APP Sensor 0.38 0.38 0.58 0.42 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 11.37 7.84 %
APP_ MAXDIFF PID 0 0 0 0 DEG
APP_ MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
B+ PID 12.05 14.08 14.13 14.08 VOLTS
BARO PID 98 (14.21) 155.19 98 (14.21) 155.19 98 (14.21) 155.19 98 (14.21) 155.19 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_ POSS PID 82 82 83 83 NUMERIC VALUE
BRKOVR_ ACTION PID 0 0 0 0 NUMERIC VALUE
CHT CHT Sensor 0.61/87 (188.6) 0.60/87 (188.6) 3.23/101 (213.8) 3.36/97 (206.6) VOLTS/DEG C (DEG F)
CLRDIST PID 53.98 (33.54) 53.98 (33.54) 53.98 (33.54) 55.98 (34.78) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_ BRKOVRD PID 63.96 (39.74) 63.96 (39.74) 63.96 (39.74) 65.95 (40.98) KM (MILES)
DTCCNT PID 3 3 3 3 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 0:1 14.15:1 14.7:1 RATIO
EQ_RAT21 PID 0:1 13.80:1 14.26:1 14.65:1 RATIO
ETC_ACT PID 8.57 2.75 6.93 12.24 DEG
ETC_TRIM PID 0.48 0.48 0.51 0.51 DEG
FLI Fuel Level Sensor 14.90 (H) 14.90 (H) 14.11 (H) 12.94 (H) %
FPM PID 40.39 40.99 40.40 40.99 %
FTP FTP Sensor 2.63/21 (0) 2.61/-5 (0) 2.62/12 (0) 2.07/-959 (-0.14) VOLTS/Pa (PSI)
FTP_H2O FTP Sensor 0.07 -0.03 0.03 -3.82 NUMERIC VALUE
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM22 HO2S22 Sensor 0 0 0 0 mA
IAT IAT Sensor 1.88/37 (98.6) 1.94/36 (96.8) 1.54/46 (114.8) 1.68/42 (107.6) VOLTS/DEG C (DEG F)
INJPWR_M PID 11.99 14.05 14.02 14.02 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS1 Sensor 0 76 173 225 COUNT
KNOCK_2 KS2 Sensor 0 94 167 131 COUNT
LOAD PID 0.00 (I) 36.86 36.07 45.49 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAP MAP Sensor 98 (14.21) 42 (6.09) 42 (6.09) 62 (8.99) kPa (PSI)
MAP_GAUGE MAP Sensor (I) 59 (8.56) 59 (8.56) 39 (5.66) kPa (PSI)
MAP_V MAP Sensor 3.91 1.63 1.63 2.43 VOLTS
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_ MISFIRE PID 0 0 2 1 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_ IMPED HO2S11 Sensor 5 0.99 0.99 0.99 VOLTS
O2S11_ READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.99 0.99 0.99 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OSS_SRC OSS Sensor 0 0 1149.75 2105.25 RPM
RO2FT1 PID 0 1.85 1.22 -0.75 %
RO2FT2 PID 0 1.00 1.23 1.00 %
RPM CKP Sensor 0 592 1218.25 1733.25 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.06/18.43 4.29/14.11 4.16/16.47 4.06/18.43 VOLTS/%
TP1_LRN_ TRIM ETBTPS 15.50 15.50 15.50 15.50 DEG
TP2 ETBTPS 1.29/25.49 0.82/16.47 1.09/21.56 1.27/25.09 VOLTS/%
TP2_LRN_ TRIM ETBTPS 7.87 7.87 7.87 7.87 DEG
TP_MAXDIFF PID 0 0 0 0 %
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL TORQUE BASED DECEL NONE REQUESTED STATUS
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VCT_EXH_ ACT1 PID 0 -0.25 19.43 34.50' DEG
VCT_EXH_ ACT2 PID 0 0 0.37 0.37 DEG
VCT_EXH_ DIF1 PID 0 0.18 0.06 -0.31 DEG
VCT_EXH_ DIF2 PID 0 0 -0.37 -0.37 DEG
VCT_INT_ ACT1 PID 0 0.25 -19.06 -33.68 DEG
VCT_INT_ ACT2 PID 0 0 -18.93 -33.56 DEG
VCT_INT_ DIF1 PID 0 0.12 -0.37 -1.18 DEG
VCT_INT_ DIF2 PID 0 0.50 -0.43 -0.93 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
CYL 1-6_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
ETC [TAC_PCT] PID 9.41 2.74 6.27 6.66 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 8.71 8.03 87.09 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPPCT PID 0 8.62 7.84 87.05 %
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module 75/OFF 36.10/ON 36.05/ON 36.10/ON %/ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
INJ1-6_OFF Injector 1-6 -- -- -- -- --/DISABLE
LFC PID OFF OFF OFF OFF ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 0 100 17.25 15.29 %
O2S21_HTR HO2S21 Sensor 0 100 17.25 13.72 %
O2_DS_ DISBL PID YES YES YES NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
SPARKADV PID 27.50 9 38 34.75 DEG
VCT_EXH_ DC1 VCT12 Solenoid 0 0 0 0 %
VCT_EXH_ DC2 VCT22 Solenoid 0 0 0 0 %
VCT_INT_ DC1 VCT11 Solenoid 0 0 45.88 45.72 %
VCT_INT_ DC2 VCT21 Solenoid 0 0 51.41 49.60 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS