LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2021 >> Escape SE Plug-In Hybrid >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System (Abs) And Stability Control >> Diagnosis And Testing >> Anti-Lock Brake System (ABS) and Stability Control >> Pinpoint Tests >> Pinpoint Test Z: Module Configuration Concern
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Pinpoint Test Z: Module Configuration Concern

Normal Operation and Fault Conditions 

During new module installation, configuration files are loaded into the new module being replaced. If a discrepancy is detected between the modules or an incomplete programming procedure is carried out, a DTC is set.

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Condition
ABS C1018:61 Regenerative Braking: Signal Calculation Failure Sets due to incomplete or improper module programming procedures.
ABS C101F:46 Generic Valve Failure: Calibration/Parameter Memory Failure Sets due to incomplete or improper module programming procedures.
ABS C101F:49 Generic Valve Failure: Internal Electronic Failure Sets due to incomplete or improper module programming procedures.
ABS U0300:51 Internal Control Module Software Incompatibility: Not Programmed Sets due to incomplete or improper module programming procedures.
ABS U2017:57 Control Module Software #2: Invalid/Incompatible Software Component Sets if the RSC calibration variant and the ABS module configuration do not match.
ABS U2017:93 Control Module Software #2: No Operation Sets if the RSC control logic cannot initialize after stable driving conditions are detected. This is usually due to an incomplete or improper module programming procedures.
ABS U2018:57 Control Module Software #3: Invalid/Incompatible Software Component Sets if the selectable drive mode software and the ABS module configuration do not match.
ABS U2024:51 Control Module Cal-Config Data: Not Programmed Sets due to incomplete or improper module programming procedures.
ABS U2100:00 Initial Configuration Not Complete: No Sub Type Information Sets due to incomplete or improper module programming procedures.
ABS U2101:00 Control Module Configuration Incompatible: No Sub Type Information Sets due to incomplete or improper module programming procedures.
ABS U2200:00 Control Module Configuration Memory Corrupt: No Sub Type Information Sets due to incomplete or improper module programming procedures.

Possible Sources 

PINPOINT TESTS Z: MODULE CONFIGURATION CONCERN