LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2021 >> Escape Titanium Plug-In Hybrid >> Repair and Diagnosis (Single Page) >> Brakes >> Brakes Control Systems >> Abs Guided Routine - Pinpoint Tests G - ZA >> Pinpoint Tests W: Abs Module Communication Concern With HVAC Module >> Normal Operation And Fault Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Normal Operation And Fault Conditions

With the ignition ON, the HVAC control module sends messages to the GWM over the MS-CAN , The GWM relays these messages to the ABS module over the FD-CAN . If the ABS module does not receivethese messages within the allotted time frame or if the messages contain invalid data, the module sets a DTC . This can be due to a HVAC control module failure, a circuit failure on the network or an excessiveload on the network. For information on the messages sent to the ABS module by the HVAC controlmodule, REFER to:  ANTI-LOCK BRAKE SYSTEM (ABS) AND STABILITY CONTROL - SYSTEM OPERATION AND COMPONENT DESCRIPTION  . 

DTC Fault Trigger Conditions 

DTC  Description  Fault Trigger Condition 
U0164:00 Lost Communication With HVAC Control Module 'A': No Sub Type Information This DTC sets when the ABS module does not receive any auto hold messages from the HVAC control module within the allowed time.
U0424:86 Invalid Data Received from HVAC Control Module 'A': Signal Invalid This DTC sets when the ABS module receives the messages from the HVAC control module, but the messages contain invalid data.