LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2021 >> Escape Titanium Plug-In Hybrid >> Repair and Diagnosis >> External Pages >> Different car >> Section 496 (Abs Guided Routine) >> Pinpoint Tests >> Pinpoint Tests Z: Module Configuration Concern >> Normal Operation and Fault Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Normal Operation and Fault Conditions

WARNING: This page is about a different car, the 2020 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.

During new module installation, configuration files are loaded into the new module being replaced. If a discrepancy is detected between the modules or an incomplete programming procedure is carried out, a DTC sets. 

PPT Z ABS MODULE DTC FAULT TRIGGER CONDITIONS

DTC Description Fault Trigger Conditions
P05D3-57 Driver Mode Select Switch "A" Range/Performance: Invalid/Incompatible Software Component This DTC sets due to incomplete or improper module programming procedures. The module must be reconfigured using as-built data.
U2017:93 Control Module Software 2: No Operation This DTC sets if the RSC control logic cannot initialize after stable driving conditions are detected. This is usually due to an incomplete or improper module programming procedures.
U2100:46 Initial Configuration Not Complete: Calibration/Parameter Memory Failure This DTC is preset in a new ABS module and clears automatically when the ABS module is configured correctly. This DTC also sets due to incomplete or improper module programming procedures.
U2100:51 Initial Configuration Not Complete: Not Programmed This DTC is preset in a new ABS module and clears automatically when the ABS module is configured correctly. This DTC also sets due to incomplete or improper module programming procedures.
U2100:56 Initial Configuration Not Complete: Invalid/Incompatible Configuration This DTC sets due to incomplete or improper module programming procedures.
U2100:57 Initial Configuration Not Complete: Invalid/Incompatible Software Component This DTC is preset in a new ABS module and clears automatically when the ABS module is configured correctly. This DTC also sets due to incomplete or improper module programming procedures.
U2101:55 Control Module Configuration Incompatible: Not Configured This DTC sets due to incomplete or improper module programming procedures.
U2101:56 Control Module Configuration Incompatible: Invalid/Incompatible Configuration This DTC sets due to incomplete or improper module programming procedures.
U2101:57 Control Module Configuration Incompatible: Invalid/Incompatible Software Component This DTC sets due to incomplete or improper module programming procedures.
U2200:00 Control Module Configuration Memory Corrupt: No Sub Type Information This DTC sets due to incomplete or improper module programming procedures.
U2200:83 Control Module Configuration Memory Corrupt: Value of Signal Protection Calculation Incorrect This DTC sets due to incomplete or improper module programming procedures.