During new module installation, configuration files are loaded into the new module being replaced. If a discrepancy is detected between the modules or an incomplete programming procedure is carried out, a DTC sets.
PPT Z ABS MODULE DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| C1018:61 | Regenerative Braking: Signal Calculation Failure | Sets due to incomplete or improper module programming procedures. |
| C101F:46 | Generic Valve Failure: Calibration/Parameter Memory Failure | Sets due to incomplete or improper module programming procedures. |
| C101F:49 | Generic Valve Failure: Internal Electronic Failure | Sets due to incomplete or improper module programming procedures. |
| U0300:51 | Internal Control Module Software Invompatibility: Not Programmed | Sets due to incomplete or improper module programming procedures. |
| U2017:57 | Control Module Software #2: Invalid/Incompatible Software Component | Sets due to incomplete or improper module programming procedures. |
| U2017:93 | Control Module Software #2: No Operation | Sets due to incomplete or improper module programming procedures. |
| U2018:57 | Control Module Software #3: Invalid/Incompatible Software Component | Sets due to incomplete or improper module programming procedures. |
| U2024:51 | Control Module Cal-Config Data: Not Programmed | This DTC is only present when a new ABS module is installed, the ABS module is flashed or the ABS module is reconfigured. |
| U2024:57 | Control Module Cal-Config Data: Invalid/Incompatible software Component | Sets due to incomplete or improper module programming procedures. |
| U2100:00 | Initial Configuration Not Complete: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |
| U2101:00 | Control Module Configuration Incompatible: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |
| U2200:00 | Control Module Configuration Memory Corrupt: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |