Pinpoint Tests RF: Reductant Pressure Sensor: Introduction
NOTE:
Regeneration may occur during normal operation. During regeneration, diagnostic procedures may display biased values. If a regeneration occurs during diagnostic procedures, allow the process to complete before continuing diagnostics.
This pinpoint test is intended to diagnose the following:
- reductant pressure sensor
- harness circuits: RDP, VREF, and SIGRTN
- reductant dosage control module (5H298)
- PCM (12A650)
| Pin | Circuit |
|---|---|
| 3 | SIGRTN (Signal Return) |
| 5 | VREF (Reference Voltage) |
| 4 | RDP (Reductant Pressure) |
| Pin | Circuit |
|---|---|
| 55 | SIGRTN (Signal Return) |
| 68 | VREF (Reference Voltage) |
| 40 | RDP (Reductant Pressure) |