Pinpoint Test Z: Module Configuration Concern
Normal Operation and Fault Conditions
During new module installation, configuration files are loaded into the new module being replaced. If a discrepancy is detected between the modules or an incomplete programming procedure is carried out, a DTC is set.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Condition |
|---|---|---|
| ABS B10DA:51 | PATS Target Identifier: Not Programmed | Sets if there is no immobilizer target identification stored in EEPROM due to incomplete or improper module programming procedures. |
| ABS C052B:93 | ABS Pump Motor Control Range/Performance: No Operation | Sets due to incomplete or improper module programming procedures. |
| ABS C101F:46 | Generic Valve Failure: Calibration/Parameter Memory Failure | Sets due to incomplete or improper module programming procedures. |
| ABS C101F:49 | Generic Valve Failure: Internal Electronic Failure | Sets due to incomplete or improper module programming procedures. |
| ABS U0300:51 | Internal Control Module Software Incompatibility: Not Programmed | Sets due to incomplete or improper module programming procedures. |
| ABS U2017:57 | Control Module Software #2: Invalid/Incompatible Software Component | Sets due to incomplete or improper module programming procedures. |
| ABS U2017:93 | Control Module Software #2: No Operation | Sets due to incomplete or improper module programming procedures. |
| ABS U2018:57 | Control Module Software #3: Invalid/Incompatible Software Component | Sets due to incomplete or improper module programming procedures. |
| ABS U2024:51 | Control Module Cal-Config Data: Not Programmed | This DTC is only present when a new ABS module is installed, the ABS module is flashed or the ABS module is reconfigured. |
| ABS U202B:62 | In-Use Application Signing Key: Signal Compare Failure | Sets due to the software level of the module, development versus production. |
| ABS U2100:00 | Initial Configuration Not Complete: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |
| ABS U2101:00 | Control Module Configuration Incompatible: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |
| ABS U2200:00 | Control Module Configuration Memory Corrupt: No Sub Type Information | Sets due to incomplete or improper module programming procedures. |
Possible Sources
- Incomplete programming procedure
- Improper programming procedure
- EBB unit (HCU and ABS module assembly)