| B1081:07 |
Left Temperature Damper Motor: Mechanical Failures |
GO to Pinpoint Test E |
| B1081:11 |
Left Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test E |
| B1081:12 |
Left Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test E |
| B1081:13 |
Left Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test E |
| B1083:07 |
Recirculation Damper Motor: Mechanical Failures |
GO to Pinpoint Test F |
| B1083:11 |
Recirculation Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test F |
| B1083:12 |
Recirculation Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test F |
| B1083:13 |
Recirculation Damper Motor: Circuit Open |
GO to Pinpoint Test F |
| B1086:07 |
Air Distribution Damper Motor: Mechanical Failures |
GO to Pinpoint Test G |
| B1086:11 |
Air Distribution Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test G |
| B1086:12 |
Air Distribution Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test G |
| B1086:13 |
Air Distribution Damper Motor: Circuit Open |
GO to Pinpoint Test G |
| B10AF:11 |
Blower Fan Relay: Circuit Short To Ground |
GO to Pinpoint Test K |
| B10AF:12 |
Blower Fan Relay: Circuit Short To Battery |
GO to Pinpoint Test L |
| B10AF:13 |
Blower Fan Relay: Circuit Open |
GO to Pinpoint Test K |
| B10B5:11 |
Left Panel Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test R |
| B10B5:15 |
Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test R |
| B10B6:11 |
Left Floor Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test R |
| B10B6:15 |
Left Floor Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test R |
| B10B8:63 |
Push Buttons: Circuit/Component Protection Time-Out |
GO to Pinpoint Test V |
| B10B9:12 |
Blower Control: Circuit Short To Battery |
GO to Pinpoint Test K |
| B10B9:14 |
Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test K |
| B10B9:14 |
Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test L |
| B11E5:11 |
Left HVAC Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test E |
| B11E5:15 |
Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test E |
| B11E7:11 |
Air Distribution Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test G |
| B11E7:15 |
Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test G |
| B11F0:11 |
Air Intake Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test F |
| B11F0:15 |
Air Intake Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test F |
| B12CA:11 |
Start/Stop "Eco-Start" Status Indicator: Circuit Short To Ground |
GO to Pinpoint Test U |
| B12CA:15 |
Start/Stop "Eco-Start" Status Indicator: Circuit Short To Battery Or Open |
GO to Pinpoint Test U |
| B1A69:11 |
Humidity Sensor: Circuit Short To Ground |
GO to Pinpoint Test C |
| B1A69:15 |
Humidity Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test C |
| B1B71:11 |
Evaporator Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test D |
| B1B71:15 |
Evaporator Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test D |
| C1B14:11 |
Sensor Supply Voltage A: Circuit Short To Ground |
GO to Pinpoint Test T |
| C1B14:12 |
Sensor Supply Voltage A: Circuit Short To Battery |
GO to Pinpoint Test T |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test M |
| U0151:00 |
Lost Communication With Restraints Control Module: No Sub Type Information |
GO to Pinpoint Test N |
| U0155:00 |
Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information |
GO to Pinpoint Test O |
| U0253:00 |
Lost Communication With Accessory Protocol Interface Module: No Sub Type Information |
GO to Pinpoint Test P |
| U0401:00 |
Invalid Data Received from ECM/PCM A: No Sub Type Information |
GO to Pinpoint Test Y |
| U0401:82 |
Invalid Data Received from ECM/PCM A: Alive/Sequence Counter Incorrect/Not Updated |
GO to Pinpoint Test Y |
| U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test Y |
| U0422:81 |
Invalid Data Received From Body Control Module: Invalid Serial Data Received |
GO to Pinpoint Test Y |
| U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test Q |
| U2024:51 |
Control Module Cal-Config Data: Not Programmed |
GO to Pinpoint Test Z |
| U2100:00 |
Initial Configuration Not Complete: No Sub Type Information |
GO to Pinpoint Test Z |
| U2101:00 |
Control Module Configuration Incompatible: No Sub Type Information |
GO to Pinpoint Test Z |
| U2200:00 |
Control Module Configuration Memory Corrupt: No Sub Type Information |
GO to Pinpoint Test Z |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AA |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test W |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test X |
| P0532:00 |
A/C Refrigerant Pressure Sensor "A" Circuit Low: No Sub Type Information |
GO to Pinpoint Test A |
| P0533:00 |
A/C Refrigerant Pressure Sensor "A" Circuit High: No Sub Type Information |
GO to Pinpoint Test A |
| P0645:00 |
A/C Clutch Relay Control Circuit: No Sub Type Information |
GO to Pinpoint Test AF |
| P06A0:00 |
Variable A/C Compressor Control Circuit: No Sub Type Information |
GO to Pinpoint Test B |
| P1464:00 |
A/C Demand Out Of Self Test Range: No Sub Type Information |
GO to Pinpoint Test J |
| P193E:00 |
A/C Clutch Request Signal: No Sub Type Information |
GO to Pinpoint Test S |