| 2.3L EcoBoost 175A |
| Generator amps at 80.6°F (27°C) |
90 amps at 700 rpm (min) to 155 amps at 2, 400 rpm (max) |
| Generator pulley ratio |
2.47:1 |
| Generator pulley replaceable |
Yes |
| Generator pulley type |
Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type |
Electronic internal with generator |
| 5.0L Ti-VCT - 175A |
| Generator amps at 80.6°F (27°C) |
70 amps at 600 rpm (min) to 155 amps at 2, 400 rpm (max) |
| Generator pulley ratio |
2.45:1 |
| Generator pulley replaceable |
No |
| Generator pulley type |
One-Way Clutch (OWC) |
| Voltage regulator type |
Electronic internal with generator |
| 5.2L Ti-VCT - 175A (base) |
| Generator amps at 80.6°F (27°C) |
80 amps at 650 rpm (min) to 155 amps at 2, 400 rpm (max) |
| Generator pulley ratio |
2.45:1 |
| Generator pulley replaceable |
No |
| Generator pulley type |
One-Way Clutch (OWC) |
| Voltage regulator type |
Electronic internal with generator |
| 5.2L Ti-VCT - 200A (optional) |
| Generator amps at 80.6°F (27°C) |
100 amps at 650 rpm (min) to 185 amps at 2, 400 rpm (max) |
| Generator pulley ratio |
2.45:1 |
| Generator pulley replaceable |
No |
| Generator pulley type |
One-Way Clutch (OWC) |
| Voltage regulator type |
Electronic internal with generator |