LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2023 >> Escape ST-Line Select >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> DTC Index (Acceleration Control - Electronic Engine Control) >> Charging System DTCS >> 2.0L EcoBoost (177kW/240PS) - MI4
April 5, 2026: LEMON Manuals is launched! Read the announcement.

2.0L EcoBoost (177kW/240PS) - MI4

DTC Description Action
B11DB:02 Battery Monitoring Module "A": General Signal Failure GO to Pinpoint Test E
B11DB:08 Battery Monitoring Module "A": Bus Signal / Message Failure GO to Pinpoint Test E
B11DB:09 Battery Monitoring Module "A": Component Failure GO to Pinpoint Test E
B11DB:11 Battery Monitoring Module "A": Circuit Short To Ground GO to Pinpoint Test E
B11DB:49 Battery Monitoring Module "A": Internal Electronic Failure GO to Pinpoint Test I
B11DB:55 Battery Monitoring Module "A": Not Configured GO to Pinpoint Test J
B11DB:9A Battery Monitoring Module "A": Component or System Operating Conditions GO to Pinpoint Test E
B130C:12 Load Shed Control: Circuit Short To Battery GO to Pinpoint Test K
B130C:14 Load Shed Control: Circuit Short To Ground or Open GO to Pinpoint Test K
B1438:03 Battery Current Sensor: FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failure GO to Pinpoint Test E
B1489:11 Battery Monitoring System (BMS) Sensor Power Circuit Short To Ground GO to Pinpoint Test E
B11D9:16 Vehicle battery - circuit voltage below threshold GO to Pinpoint Test B
B11D9:17 Vehicle battery - circuit voltage above threshold GO to Pinpoint Test A
P0562 System Voltage Low GO to Pinpoint Test B
P0563 System Voltage High GO to Pinpoint Test A
P065B Generator Control Circuit Range/Performance GO to Pinpoint Test B
P065C Generator Mechanical Performance GO to Pinpoint Test B
P0A3B Generator Over Temperature GO to Pinpoint Test G
P1397 System Voltage Out Of Self-Test Range If combined with P0562, GO to Pinpoint Test B If combined with P0563, GO to Pinpoint Test A
U012D Lost Communication With Generator Control Module GO to Pinpoint Test F
U042E Invalid Data Received From Generator Control Module GO to Pinpoint Test F