Diagnostic Trouble Code (DTC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .
| Module | DTC | Description | Action |
|---|---|---|---|
| BCM | B11DB:02 | Battery Monitoring Module 'A': General Signal Failure | GO to Pinpoint Test G |
| BCM | B11DB:08 | Battery Monitoring Module 'A': Bus Signal / Message Failure | GO to Pinpoint Test G |
| BCM | B11DB:09 | Battery Monitoring Module 'A': Component Failure | GO to Pinpoint Test G |
| BCM | B11DB:11 | Battery Monitoring Module 'A': Circuit Short To Ground | GO to Pinpoint Test G |
| BCM | B11DB:49 | Battery Monitoring Module 'A': Internal Electronic Failure | GO to Pinpoint Test J |
| BCM | B11DB:55 | Battery Monitoring Module 'A': Not Configured | GO to Pinpoint Test K |
| BCM | B11DB:9A | Battery Monitoring Module 'A': Component or System Operating Conditions | GO to Pinpoint Test G |
| BCM | B130C:12 | Load Shed Control: Circuit Short To Battery | GO to Pinpoint Test G |
| BCM | B130C:14 | Load Shed Control: Circuit Short To Ground Or Open | GO to Pinpoint Test G |
| PCM | P0562:00 | System Voltage Low: No Sub Type Information | GO to Pinpoint Test B |
| PCM | P0563:00 | System Voltage High: No Sub Type Information | GO to Pinpoint Test A |
| PCM | P065B:00 | Generator 'A' Control Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test B |
| PCM | P065C:00 | Generator 'A' Mechanical Performance: No Sub Type Information | GO to Pinpoint Test B |
| PCM | P0A3B:00 | Generator 'A' Over Temperature: No Sub Type Information | GO to Pinpoint Test D |
| PCM | P0A5A:00 | Generator Current Sensor Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test F |
| PCM | P0A5B:00 | Generator Current Sensor Circuit Low: No Sub Type Information | GO to Pinpoint Test F |
| PCM | P0A5C:00 | Generator Current Sensor Circuit High: No Sub Type Information | GO to Pinpoint Test F |
| PCM | U012D:00 | Lost Communication With Generator 'A' Control Module: No Sub Type Information | GO to Pinpoint Test H |
| PCM | U042E:00 | Invalid Data Received From Generator 'A' Control Module: No Sub Type Information | GO to Pinpoint Test H |