Pinpoint Tests: Notes
The Horn Is Inoperative
Refer to Wiring Diagrams Cell 44 for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Horn .
DTC Chart
| DTC | Description | Fault Trigger Condition |
|---|---|---|
| B1C55:12 | Horn Relay: Circuit Short to Battery | A CMDTC that sets when the BCM detects a short to voltage on the horn relay control circuit. The BCM disables the horn when this DTC is set. |
| B1C55:14 | Horn Relay: Circuit Short to Ground or Open | This DTC sets when the BCM detects a short to ground or an open on the horn relay control circuit. |
Possible Sources
- Fuse
- Wiring, terminals or connectors
- Clockspring
- Horn
- Horn relay
- Horn switch (part of driver airbag)
- BCM
Visual Inspection and Diagnostic Pre-checks
Verify the BJB fuse 50 (20A) is OK.