Starter Amperage Draw Test

For information on Ford Color Coded Illustrations refer to OEM COLOR CODING .

NOTE: Make sure the test is performed with the engine at 16 deg.C or above.
  1. Make sure the battery is fully charged.For additional information, refer to: Specifications .
  2. Disable the fuel system. For gasoline engines, refer to: For additional information, refer to: FUEL SYSTEM PRESSURE RELEASE . For diesel engines, refer to: Wiring article for fuel pump inline connector location.
  3. Connect the 0-500-amp probe to the starter B+ Cable and to the VCMM.
  4. Connect the VCMM and use the Oscilloscope option scaled to 100/A/Div. Add PIDS "Ambient Air Temp" and "Engine RPM".
  5. Crank the engine, not more than 6 seconds at a time.
    NOTE: Allow 2 minutes between tests to allow for starter cooling to prevent overheat and damage to the motor.
  6. Record the results, specifically Ambient Air Temperature (AAT), Starter Current (Current Clamp), and Cranking speed (PCM signal Engine_Speed).
  7. Compare the results to the specifications in the Service Information.For additional information, refer to: SPECIFICATIONS  .
  8. If both signals do not meet specification, replace the starter motor.For additional information, refer to: Starter Motor  .
  9. Clear all CMT DTC.