| C1002:77 |
Left Power Running Board Stow: Commanded Position Not Reachable |
GO to Pinpoint Test L |
| C1003:77 |
Right Power Running Board Stow: Commanded Position Not Reachable |
GO to Pinpoint Test L |
| C1004:77 |
Right Power Running Board Deploy: Commanded Position Not Reachable |
GO to Pinpoint Test L |
| C1005:77 |
Left Power Running Board Deploy: Commanded Position Not Reachable |
GO to Pinpoint Test L |
| C1006:11 |
Left Power Running Board Motor: Circuit Short To Ground |
GO to Pinpoint Test D |
| C1006:12 |
Left Power Running Board Motor: Circuit Short To Battery |
GO to Pinpoint Test D |
| C1006:13 |
Left Power Running Board Motor: Circuit Open |
GO to Pinpoint Test D |
| C1006:19 |
Left Power Running Board Motor: Circuit Current Above Threshold |
GO to Pinpoint Test D |
| C1007:11 |
Right Power Running Board Motor: Circuit Short To Ground |
GO to Pinpoint Test E |
| C1007:12 |
Right Power Running Board Motor: Circuit Short To Battery |
GO to Pinpoint Test E |
| C1007:13 |
Right Power Running Board Motor: Circuit Open |
GO to Pinpoint Test E |
| C1007:19 |
Right Power Running Board Motor: Circuit Current Above Threshold |
GO to Pinpoint Test E |
| C1008:3A |
Left Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses |
GO to Pinpoint Test F |
| C1008:93 |
Left Power Running Board Position/Motion Sensor: No Operation |
GO to Pinpoint Test F |
| C1009:3A |
Right Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses |
GO to Pinpoint Test F |
| C1009:93 |
Right Power Running Board Position/Motion Sensor: No Operation |
GO to Pinpoint Test F |
| C1B14:11 |
Sensor Supply Voltage A: Circuit Short To Ground |
GO to Pinpoint Test F |
| C1B14:12 |
Sensor Supply Voltage A: Circuit Short To Battery |
GO to Pinpoint Test F |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test J |
| U0146:00 |
Lost Communication With Serial Data Gateway 'A': No Sub Type Information |
GO to Pinpoint Test G |
| U0422:00 |
Invalid Data Received From Body Control Module: No Sub Type Information |
GO to Pinpoint Test N |
| U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test K |
| U3000:09 |
Control Module: Component Failure |
GO to Pinpoint Test M |
| U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test M |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test M |
| U3000:4B |
Control Module: Over Temperature |
GO to Pinpoint Test M |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test H |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test I |